Schneider Electric LC1F1250MD LC1F Series Contactor, 230 VDC v coil, 1260 A, 3NO contact, 3 poles
NEMA & IEC Contactors
PDW~13597816
MFG #: LC1F1250MD
Square D™
0.00000
/ ea
Schneider Electric LC1F1250MD, Contactor, LC1F Series, 230 VDC Coil, 1260 A Maximum Load Current, 3 Pole, 50/60 Hz Frequency, 120 W Wattage, 3NO Contact Configuration, 1260 A Contact, Screw clamp Connection, 13.31 in H x 12.17 in W x 104 in D Size, Screw Clamp Terminal, 1200 cycles Operating Cycles, 23 to 104 deg F Operating, Plate Mounting, 13.31 in H x 12.17 in W x 10.04 in D Dimensions
- 360 Degree View URL - 360(360 Degree View URL)
- 360 Degree View URL - index.html?pid=11003&id=16852092360Den&ext=webp(360 Degree View URL)
- Brochure URL - 11003_FVGKD9YWJERZPNAC.zip(Brochure URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=LC1F1250F7_3D-simplified.stp(Computer~Aided [CAD|BIM] Model URL)
- Install Instructions 1 URL - 11003_YH4170JEKUWXT36R.pdf(Install Instructions 1 URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Service Manual URL - 11003_AYSDG6MEZ7KJPOX3.pdf(Service Manual URL)
- Service Manual URL - 11003_VNUS936BHZFE8MO7.pdf(Service Manual URL)
- Service Manual URL - files?p_enDocType=Circularity+Profile&p_File_Name=EoLI_ENVEOLI1102006_V3.pdf(Service Manual URL)
- Spec Sheet URL - 11003_SMJZOINYDB18A3X4.pdf(Spec Sheet URL)
- Applications
- Features
Resistive load |
The TeSys F contactors and overload relays offer proven performance for resistive loads or large motor starting applications such as fans, crushers, pumps, compressors and overhead cranes |
Front mount dust tight auxiliary contact blocks |
Pneumatic time delay blocks |
Solid State Overload Relays |
They are ambient compensated and include single phase sensitivity for phase unbalance and phase loss protection |
They also include the following features Isolated N.C. trip contact, N.O. alarm contact |
Manual reset button |
Rotary dial for adjustable current settings with tamper resistant window |
Test trip button |
Resistive load contactor application |
Resistive load contactor application |
8 kV uimp rated impulse withstand voltage |
III overvoltage category |
3000 A 104 deg F (40 deg C) - 3 min8000 A 104 deg F (40 deg C) - 10 s5200 A 104 deg F (40 deg C) - 30 s4000 A 104 deg F (40 deg C) - 1 min2000 A 104 deg F (40 deg C) - 10 min icw rated short-time withstand current |
0.12 mOhm - Ith 1260 A 50 Hz average impedance |
1000 V IEC 60947-4-1 1500 V VDE 0110 group C ui rated insulation voltage |
60 to 70 ms closing40 to 50 ms opening operating time |
LC1F compatibility code |
TH protective treatment |