Schneider Electric Altivar™ 930 Square D™ ATV930D22N4 3-Phase Standard AC Variable Speed Drive With Braking Chopper Unit, Category C2/C3 Integrated EMC Filter, 400 to 480 VAC, 29.9/34.1/34.4/39.6 A, 25 hp, 30 hp, 211 mm W x 235 mm D
AC Variable Frequency Drives
1138600
MFG #: ATV930D22N4
Square D™
6261.17000
/ ea
Schneider Electric Altivar™ 930 Square D™ AC Variable Speed Drive, 3-Phase Standard, 400 to 480 VAC, 29.9/34.1/34.4/39.6 A, 25 hp, 30 hp, 211 mm Width, 235 mm Depth, 545.9 mm Height, NEMA 1/IP20/IP21 Enclosure, LED Display, Wall Mounting
- 360 Degree View URL - index.html?pid=11003&id=13853613360Den&ext=webp(360 Degree View URL)
- Brochure URL - 11003_9PT1LU7VOI5CXNW3.pdf(Brochure URL)
- Install Instructions 1 URL - 11003_ABY71PWCO9X2L5VT.pdf(Install Instructions 1 URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=MCADID0001041_2D-right.dxf(Computer~Aided [CAD|BIM] Model URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=ATV930D22N4_2D.dwg(Computer~Aided [CAD|BIM] Model URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=ATV930D22N4_2D.dwf(Computer~Aided [CAD|BIM] Model URL)
- Install Instructions 1 URL - 11003_S8VL0YZ7NK25AJGC.pdf(Install Instructions 1 URL)
- Service Manual URL - 11003_TZQPN06XC1HBWV74.pdf(Service Manual URL)
- Service Manual URL - 11003_5BXIH2GWCF3ZAVE7.pdf(Service Manual URL)
- Tech Bulletin URL - files?p_enDocType=Data Bulletin&p_File_Name=8800DB1705.pdf(Tech Bulletin URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Tech Drawing URL - sales?sn=ATV930D22N4(Tech Drawing URL)
- Tech Bulletin URL - 11003_8B39GOI7P1SVZE4C.pdf(Tech Bulletin URL)
- Spec Sheet URL - 11003_4XKHBJ506NISGEDW.pdf(Spec Sheet URL)
- User Manual URL - 11003_3BEAXPF0CSYJOUGM.pdf(User Manual URL)
- User Manual URL(User Manual URL)
- Applications
- Features
Oil and Gas, Mining, Minerals and Metals, Food and Beverage, Water and Wastewater, Asynchronous and Synchronous and Special Motors Applications |
Variable torque standard;optimized torque mode;constant torque standard;16 preset speeds;Control screw terminal 0.5...1.5 mm² AWG 20...AWG 16;line side screw terminal 10...16 mm² AWG 8...AWG 6;DC bus screw terminal 10...16 mm² AWG 8...AWG 6;motor screw terminal 16 mm² AWG 6;1;Thermal protection motor;safe torque off motor;motor phase break motor;thermal protection drive;safe torque off drive;overheating drive;overcurrent between output phases and earth drive;overload of output voltage drive;short-circuit protection drive;motor phase break drive;overvoltages on the DC bus drive;line supply overvoltage drive;line supply undervoltage drive;line supply phase loss drive;overspeed drive;break on the control circuit drive;External supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection;internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection;internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection |
Ethernet/IP serial Modbus TCP communication |
Performance on motor control with an overload torque up to 1.8 Tn in an open or closed loop |
Asynchronous, synchronous, special motors: all efficiency classes, brand independent, permanent magnet motors, torque motors, conical sliding rotor, reluctance motor |
Integrated Ethernet/IP and Modbus TCP dual port, cyber security (Achilles level 2) |
Smart integration in PlantStruxure and Foxboro Evo process automation system |
Optimized energy efficiency, detection of energy consumption drift of the installation |
Adaptation to the process by dedicated functions with modular design |
Embedded safety functions STO SIL 3 |
Master/slave and load sharing with drive to drive capability |
Torque sharing on elastic coupling |
Torque sharing on elastic coupling |
Contextual access to technical documentation through dynamic QR code |
Continuous and historical real time measurements with customizable dashboards |
Predictive maintenance |
39.6 A at 380 VAC normal duty, 34.4 A at 480 VAC normal duty, 34.1 A at 380 VAC heavy duty, 29.9 A at 480 VAC heavy duty amperage rating |
30 hp at normal duty, 25 hp at heavy duty horsepower rating |
16 preset speeds, STO (safe torque off) SIL 3 |
0.5 to 1.5 sq-mm control, 10 to 16 sq-mm DC bus, 10 to 16 sq-mm line side bus, 16 sq-mm motor screw terminal |
External supply for digital inputs: 24 VDC (19 to 30 V) current =1.25 mA (overload and short circuit protection) internal supply for reference potentiometer (1 to 10 kOhm): 10.5 VDC +/- 5 % current 10 mA (overload and short circuit protection) internal supply for digital inputs and STO: 24 VDC (21 to 27 V) current =200 mA (overload and short circuit protection) |
Forced convection, optimized torque mode, variable torque standard, constant torque standard, motor - thermal protection, safe torque off, motor phase break, drive - thermal protection, safe torque off, overheating, overcurrent between output phases and earth, overload of output voltage, short circuit protection, motor phase break, overvoltage on the DC bus, line supply overvoltage, line supply under voltage, line supply phase loss, over speed, break on the control circuit |