Edison TCF10RN CUBEFuse® TCF Time Delay Low-Peak Fuse, 10 A, 600 VAC/300 VDC, 300 kA at 600 VAC/100 kA at 300 VDC Interrupt
Cartridge Fuses
541024
MFG #: TCF10RN
Bussmann
60.55000
/ ea
Edison CUBEFuse® Low-Peak Fuse, Time Delay, Series: TCF, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Non-Rejection, 10 A, 600 VAC/300 VDC, 300 kA at 600 VAC/100 kA at 300 VDC Interrupt, Class: CF, 10 s at 500% Response, Plug In Terminal, 35 mm DIN Rail/Chassis Mount, Cartridge Square Body, Dual Element, Glass Filled Polyethersulfone, 1.88 in L x 0.75 in W x 1 in H Body Size
- Brochure URL - COBUSSE01827_20.pdf(Brochure URL)
- Catalog URL - Edison_TCF10_Brochure.pdf(Catalog URL)
- Spec Sheet URL - skuPage.TCF10RN.pdf(Spec Sheet URL)
- Spec Sheet URL - 10973_1ZKMVTFY2BWI7QDU.pdf(Spec Sheet URL)
- Spec Sheet 1 URL - Edison_TCF100RN_Specification_Sheet_1.pdf(Spec Sheet 1 URL)
- http://www.bussmann.com(Seller Home Page URL)
- Video - https://www.youtube.com/embed/YMvqUyoETXk(Video)
- Tech Drawing URL - Bus_Ele_DS_9000_TCF_TCF_RN.pdf(Tech Drawing URL)
- Applications
- Features
Ind Facilities & Factories - Facility: Safety and Security SystemsDatacenters - Facilities: Power DistributionCommercial / Institutional Buildings / Structures - Critical PowerInd Facilities & Factories - Facility: Power Distribution and ControlStationary Machinery and Equipment Outside Factory - HVAC |
Finger safe |
Finger safe |
The indicating version features easyID™ open fuse technology for faster troubleshooting and reduced downtime |
Faster response to damaging faults to help reduce destructive thermal and magnetic forces |
True dual element fuse construction with a minimum of 10 sec time delay at 500% of rating |
Long time delay minimizes nuisance circuit openings due to temporary overloads and transient surges |
No venting of arc or molten metal and gases during opening |
Robust cycling and inrush current withstand |
Low let through currents under fault conditions |
10 sec at 500% response time |
Low let through currents under fault conditions |
Provides type 2 no damage in protection for IEC motors starters when properly sized |
Easy selective coordination with any other Cooper Bussmann low peak class CC, L, J and RK1 fuse with simple 2:1 amp ration between upstream and downstream fuses |
-40 to 80 deg C operating temperature |
300 kA RMS symmetrical (UL) and 300 kA RMS symmetrical (CSA) at 600 VAC, 100 kA (UL and CSA) at 300 VDC interrupt rating |
Copper alloy terminals, electroless tin terminal plating, energetic chemical indicator |
10 sec at 500% response time |