Fluke® I30 AC/DC Current Clamp, 20 A/300 VAC/VDC, 20 kHz

Clamp Meters
500991 MFG #: I30
Fluke®
646.99000 / ea
  • AC Current Accuracy: +/-1% +/-2 mA at 25 deg C
  • Alternate Catalog Number: 2584920
  • Amperage Rating: 30 A
  • Application: Measure Current
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: I30
  • Color: Yellow, Black, Brown
  • Country of Origin: CN
  • Currency: USD
  • Diameter: .75 in
  • Dimensions: 3/4 in Dia x 8.94 in L x 2.8 in W x 1 in H
  • Enclosure: Hard plastic
  • EU RoHS Indicator: U
  • Gross Weight Per Pack: 0.9480 lb
  • Gross Weight per Pack Metric: 0.43
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 9030908922
  • Height: 2.48 in
  • Height [Metric]: 6.3000 cm
  • Length: 9.92 in
  • Length [Metric]: 25.1998 cm
  • Material: Hard Plastic
  • Measuring Range: 5 mA to 30 A dc, 30 mA to 20 A ac rms
  • Model: Fluke i30
  • Operating Temperature: 0 to 50 °C
  • Power Source: 9 VDC Alkaline Battery
  • Repeatability: None
  • Resolution: ± 1 mA Milliamp
  • Standard: BS EN 61010-1:2001; BS EN 61010-2-032:2002; BS EN 61010-031:2002; 300 Vrms, Category III, Pollution Degree 2; Use of the probe on uninsulated conductors is limited to 300 V ac rms or dc and frequencies below 1 kHz
  • Tip Material: Hard Plastic
  • Type: Current Clamp
  • UNSPSC: 41111905
  • UPC 11: 09596934509
  • UPC 12: 095969345095
  • Width: 3.98 in
  • Width [Metric]: 10.1001 cm
  • Stock Status: NONSTOCK
  • Brand: Fluke®
  • Manufacturer: Fluke Corporation
  • Electrical Ratings: 30 A, 300 VAC/VDC
  • Frequency Rating: 20 kHz
The i30 current clamp is based on Hall Effect technology for use in measurement of both DC and AC current. The i30 may be used in conjunction with multimeters, recorders and other suitable recording instruments for accurate non-intrusive current measurement.
QTY
  • Applications
  • Features
Measure Current
30 mA to 30 a DC, 30 mA to 20 A AC RMS specified current range
5 mA to 30 a DC, 30 mA to 20 A AC RMS usable current range
1.4 in crest factor
100 mV/A output sensitivity
+/-1 mA resolution
>10 kOhm and <=100 pF load impedance
+/-1% relative to center reading conductor position sensitivity
DC to 20 kHz (-0.5 dB) frequency
+/-0.01% of reading/deg C temperature coefficient
9 VDC alkaline, MN1604/PP3, 30 hr low battery indicator power supply
300 VAC RMS or DC working voltage
19 mm Dia maximum conductor
4 mm safety connector output connection
Manual adjust via thumbwheel output zero
1.5 m L cable
-20 to 85 deg C storage temperature range (with battery removed)
15 to 85% non-condensing operating humidity
300 VRMS, category III, pollution degree 2