Fluke® I2000-FLEX AC Current Clamp Meter, 600 VAC/VDC, 2000 A, 10 Hz to 20 kHz

Clamp Meters
471016 MFG #: I2000 FLEX
Fluke®
559.99000 / ea
  • AC Current Accuracy: +/-1%
  • Catalog Number: I2000 FLEX
  • Color: Black
  • Country of Origin: UKN
  • Dimensions: 4.56 in H x 2.69 in W x 1.18 in D
  • Gross Weight Per Pack: 0.7000 lb
  • Operating Temperature: 0 to 70 °C
  • Power Source: (2) AA/MN 1500/LR6 Alkaline Battery
  • Safety Rating: CAT III 600 VAC
  • Standards: CAT III, EN 61010-031 - 2002, EN 61010-2-032 - 2002, EN 61010-1 - 2001, 600 VRMS, EN 61326 - 1998 and A1, A2 and A3
  • UNSPSC: 41113601
  • UPC 11: 09596934508
  • UPC 12: 09596934508
  • Stock Status: NONSTOCK
  • Brand: Fluke®
  • Manufacturer: Fluke Corporation
  • Electrical Ratings: 600 VAC/VDC, 20/200/2000 A
  • Frequency Rating: 10 Hz to 20 kHz
The i2000 is an AC current probe utilizing the Rogowski principle. It can be used to measure currents up to 2000 A when used in conjunction with multimeters, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.
QTY
  • Features
The i2000 is an AC current probe utilizing the Rogowski principle; It can be used to measure currents up to 2000 AMP when used in conjunction with multimeters, recorders or data loggers; The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas; Ideal for current measurement on thick and hard to reach conductors without breaking the circuit; Output sensitivity (AC-coupled): 1/10/100 MILV, 1 MILV/AMP; Linearity: 10 - 100 PCT of range plus/minus 0.2 PCT of reading; Noise 8 MILV AC RMS (30 AMP) 2 MILV AC RMS (300/3000 AMP); Phase error: Less than plus/minus 1 DEG (45 - 65 HZ), plus/minus 10 DEG (at 20 KHZ); Position sensitivity with cable greater than 25 MM from the coupling plus/minus 2 PCT of range; External field with cable greater than 200 MM from the head plus/minus 1 PCT of range; Battery life 200 HR, low battery ind
178 mm maximum conductor dia
It can be used to measure currents up to 2000 A
0 - 70 deg C operating
-40 to 105 deg (head), -20 to 85 deg C (electronics) storage temperature
Output sensitivity (AC-coupled) - 1 mV, 10 mV, 100 mV, 1 mV per A
Linearity - 10% to 100% of range, +/- 0.2% of reading
Noise - 8 mV AC rms (30 A), 2 mV AC rms (300 A, 3000 A)
Phase error - < +/-1 deg (45 Hz to 65 Hz), +/-10 deg (at 20 kHz)
24 in head circumference, 0.56 in head cable diameter, 1.5 in head bend radius
2 m cable length
15 - 85% humidity, 25 deg C, +/- 1% of range 45 - 65 Hz accuracy, 100 kOhm impedance, (2) AA/MN 1500/LR6 alkaline battery
Suitable for use with multimeters, recorders and data loggers
AC current range - 20 A, 200 A, 2000 A with accuracy of +/-1% of range (45 Hz to 65 Hz)