or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Fluke®
Fluke® I2000-FLEX AC Current Clamp Meter, 600 VAC/VDC, 2000 A, 10 Hz to 20 kHz
Custom_Product_Images_Illustration
Fluke®
Fluke® I2000-FLEX AC Current Clamp Meter, 600 VAC/VDC, 2000 A, 10 Hz to 20 kHz
SKU471016
MFGR #I2000 FLEX
Your Cost: $605.99/ea
The i2000 is an AC current probe utilizing the Rogowski principle. It can be used to measure currents up to 2000 A when used in conjunction with multimeters, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.
The i2000 is an AC current probe utilizing the Rogowski principle. It can be used to measure currents up to 2000 A when used in conjunction with multimeters, recorders or data loggers. The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas.
AC Current Accuracy +/-1% Catalog Number I2000 FLEX Color Black Country of Origin UKN Dimensions 4.56 in H x 2.69 in W x 1.18 in D Gross Weight Per Pack 0.7000 lb Operating Temperature 0 to 70 °C Power Source (2) AA/MN 1500/LR6 Alkaline Battery Safety Rating CAT III 600 VAC Standards CAT III, EN 61010-031 - 2002, EN 61010-2-032 - 2002, EN 61010-1 - 2001, 600 VRMS, EN 61326 - 1998 and A1, A2 and A3 UNSPSC 41113601 UPC 11 09596934508 UPC 12 09596934508 Stock Status NONSTOCK Brand Fluke® Manufacturer Fluke Corporation Electrical Ratings 600 VAC/VDC, 20/200/2000 A Frequency Rating 10 Hz to 20 kHz The i2000 is an AC current probe utilizing the Rogowski principle; It can be used to measure currents up to 2000 AMP when used in conjunction with multimeters, recorders or data loggers; The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas; Ideal for current measurement on thick and hard to reach conductors without breaking the circuit; Output sensitivity (AC-coupled): 1/10/100 MILV, 1 MILV/AMP; Linearity: 10 - 100 PCT of range plus/minus 0.2 PCT of reading; Noise 8 MILV AC RMS (30 AMP) 2 MILV AC RMS (300/3000 AMP); Phase error: Less than plus/minus 1 DEG (45 - 65 HZ), plus/minus 10 DEG (at 20 KHZ); Position sensitivity with cable greater than 25 MM from the coupling plus/minus 2 PCT of range; External field with cable greater than 200 MM from the head plus/minus 1 PCT of range; Battery life 200 HR, low battery ind 178 mm maximum conductor dia It can be used to measure currents up to 2000 A 0 - 70 deg C operating -40 to 105 deg (head), -20 to 85 deg C (electronics) storage temperature Output sensitivity (AC-coupled) - 1 mV, 10 mV, 100 mV, 1 mV per A Linearity - 10% to 100% of range, +/- 0.2% of reading Noise - 8 mV AC rms (30 A), 2 mV AC rms (300 A, 3000 A) Phase error - < +/-1 deg (45 Hz to 65 Hz), +/-10 deg (at 20 kHz) 24 in head circumference, 0.56 in head cable diameter, 1.5 in head bend radius 2 m cable length 15 - 85% humidity, 25 deg C, +/- 1% of range 45 - 65 Hz accuracy, 100 kOhm impedance, (2) AA/MN 1500/LR6 alkaline battery Suitable for use with multimeters, recorders and data loggers AC current range - 20 A, 200 A, 2000 A with accuracy of +/-1% of range (45 Hz to 65 Hz)
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
| AC Current Accuracy | +/-1% |
| Catalog Number | I2000 FLEX |
| Color | Black |
| Country of Origin | UKN |
| Dimensions | 4.56 in H x 2.69 in W x 1.18 in D |
| Gross Weight Per Pack | 0.7000 lb |
| Operating Temperature | 0 to 70 °C |
| Power Source | (2) AA/MN 1500/LR6 Alkaline Battery |
| Safety Rating | CAT III 600 VAC |
| Standards | CAT III, EN 61010-031 - 2002, EN 61010-2-032 - 2002, EN 61010-1 - 2001, 600 VRMS, EN 61326 - 1998 and A1, A2 and A3 |
| UNSPSC | 41113601 |
| UPC 11 | 09596934508 |
| UPC 12 | 09596934508 |
| Stock Status | NONSTOCK |
| Brand | Fluke® |
| Manufacturer | Fluke Corporation |
| Electrical Ratings | 600 VAC/VDC, 20/200/2000 A |
| Frequency Rating | 10 Hz to 20 kHz |
| The i2000 is an AC current probe utilizing the Rogowski principle; It can be used to measure currents up to 2000 AMP when used in conjunction with multimeters, recorders or data loggers; The flexible and lightweight measuring head allows quick and easy installation in hard to reach areas; Ideal for current measurement on thick and hard to reach conductors without breaking the circuit; Output sensitivity (AC-coupled): 1/10/100 MILV, 1 MILV/AMP; Linearity: 10 - 100 PCT of range plus/minus 0.2 PCT of reading; Noise 8 MILV AC RMS (30 AMP) 2 MILV AC RMS (300/3000 AMP); Phase error: Less than plus/minus 1 DEG (45 - 65 HZ), plus/minus 10 DEG (at 20 KHZ); Position sensitivity with cable greater than 25 MM from the coupling plus/minus 2 PCT of range; External field with cable greater than 200 MM from the head plus/minus 1 PCT of range; Battery life 200 HR, low battery ind |
| 178 mm maximum conductor dia |
| It can be used to measure currents up to 2000 A |
| 0 - 70 deg C operating |
| -40 to 105 deg (head), -20 to 85 deg C (electronics) storage temperature |
| Output sensitivity (AC-coupled) - 1 mV, 10 mV, 100 mV, 1 mV per A |
| Linearity - 10% to 100% of range, +/- 0.2% of reading |
| Noise - 8 mV AC rms (30 A), 2 mV AC rms (300 A, 3000 A) |
| Phase error - < +/-1 deg (45 Hz to 65 Hz), +/-10 deg (at 20 kHz) |
| 24 in head circumference, 0.56 in head cable diameter, 1.5 in head bend radius |
| 2 m cable length |
| 15 - 85% humidity, 25 deg C, +/- 1% of range 45 - 65 Hz accuracy, 100 kOhm impedance, (2) AA/MN 1500/LR6 alkaline battery |
| Suitable for use with multimeters, recorders and data loggers |
| AC current range - 20 A, 200 A, 2000 A with accuracy of +/-1% of range (45 Hz to 65 Hz) |