Telemecanique XMLR400M1P25 XMLR Series Fixed Differential, Pressure Sensor sensing, 5 to 10 ms response, Solid State/PNP output, 24 VDC
Pressure Sensors
PDW~11800684
MFG #: XMLR400M1P25
Telemecanique Sensors
345.00000
/ ea
Telemecanique XMLR400M1P25, Fixed Differential, XMLR Series, Pressure Sensor Sensing Method, 5 to 10 ms Response, Solid State/PNP Output, 24 VDC, 50 mA, Male connector Connection, (1) Yellow LED Light Source, 5801.51 psi Pressure, 3.46 in H x 1.61 in W x 1.65 in D Size, IP65/IP67 Enclosure, -20 to 80 deg C Operating, Environmental Conditions: -40 to 176
- 360 Degree View URL - 360(360 Degree View URL)
- Brochure URL - 11003_327LTIKVBZQF6MYS.pdf(Brochure URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=MCADID0003808_2D-right.dxf(Computer~Aided [CAD|BIM] Model URL)
- Install Instructions 1 URL - 11003_XJNCKHB127RULYQD.pdf(Install Instructions 1 URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Spec Sheet URL - 11003_EX781Z5I96V3ASJO.pdf(Spec Sheet URL)
- Applications
- Features
For the the pressure control of a large number of fluids |
Polyester front material |
0.5 kV DC uimp rated impulse withstand voltage |
Fresh water 32 to 176 deg F (0 to 80 deg C))Air -4 to 176 deg F (-20 to 80 deg C))Hydraulic oil -4 to 176 deg F (-20 to 80 deg C))Refrigeration fluid -4 to 176 deg F (-20 to 80 deg C)) controlled fluid |
464 to 5800 psi (3199.17 to 39989.59 kPa)464.12 to 5801.51 psi (32 to 400 bar)3.2 to 40 MPa adjustable range of switching point on rising pressure |
1745 psi (12 bar)1.2 MPa174 psi (1199.69 kPa) minimum differential travel |
Polyacrylamide 316L stainless steel housing material |
Any position, but disposals can falsified the measurement in case of upside down mounting operating position |
Overload protection, Reverse polarity, Overvoltage protection, Short-circuit protection type |
0 to 50 s in steps of 1 second switching output time delay |
Fast 50 msNormal 200 msSlow 600 ms display response time type |
Fast 50 msNormal 200 msSlow 600 ms display response time type |
300 ms maximum delay first up |
<= 1 % of the measuring range overall accuracy |
<= 0.5 % of the measuring range linearity error on analogue output |
<= 0.2 % of the measuring range hysteresis on analogue output |
<= 0.6 % of the measuring range measurement accuracy on switching output |
+/- 03 % of measuring range/ deg C drift of the sensitivity |
+/- 0.1 % of measuring range/ deg C drift of the zero point |
<= 1 % of the measuring range display accuracy |