Telemecanique XMLR160M2P05 XMLR Series Fixed Differential, Pressure Sensor sensing, 5 ms response, Solid State/PNP output, 24 VDC
Pressure Sensors
PDW~11800645
MFG #: XMLR160M2P05
Telemecanique Sensors
313.00000
/ ea
Telemecanique XMLR160M2P05, Fixed Differential, XMLR Series, Pressure Sensor Sensing Method, 5 ms Response, Solid State/PNP Output, 24 VDC, 50 mA, Male connector Connection, (2) Yellow LED Light Source, 145.04 psi Pressure, 3.46 in H x 1.61 in W x 1.65 in D Size, IP65/IP67 Enclosure, -20 to 80 deg C Operating, Environmental Conditions: -40 to 176
- 360 Degree View URL - 360(360 Degree View URL)
- Brochure URL - 11003_327LTIKVBZQF6MYS.pdf(Brochure URL)
- Brochure URL - files?p_enDocType=Brochure&p_File_Name=9006BR2201NAM_SensorsPano0622.pdf(Brochure URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=MCADID0003808_2D-right.dxf(Computer~Aided [CAD|BIM] Model URL)
- Install Instructions 1 URL - 11003_XJNCKHB127RULYQD.pdf(Install Instructions 1 URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Spec Sheet URL - 11003_2RAVDCEFP61T4SMQ.pdf(Spec Sheet URL)
- Applications
- Features
For local signalling, For electrical connection and G 1/4inch, For numerous industrial applications requiring display, control or regulation of pressure/vacuum levels, For pressure control or monitoring on pumps, For fluid connection, For controlling fluids such as fresh water |
Polyester front material |
0.5 kV DC uimp rated impulse withstand voltage |
Fresh water 32 to 176 deg F (0 to 80 deg C))Air -4 to 176 deg F (-20 to 80 deg C))Hydraulic oil -4 to 176 deg F (-20 to 80 deg C))Refrigeration fluid -4 to 176 deg F (-20 to 80 deg C)) controlled fluid |
186 to 2320 psi (1282.42 to 15995.84 kPa)1.28 to 16 MPa185.65 to 2320.60 psi (12.8 to 160 bar) adjustable range of switching point on rising pressure |
0.48 MPa69.6 psi (479.88 kPa)69.62 psi (4.8 bar) minimum differential travel |
Polyacrylamide 316L stainless steel housing material |
Any position, but disposals can falsified the measurement in case of upside down mounting operating position |
Overload protection, Reverse polarity, Overvoltage protection, Short-circuit protection type |
0 to 50 s in steps of 1 second switching output time delay |
Fast 50 msNormal 200 msSlow 600 ms display response time type |
Fast 50 msNormal 200 msSlow 600 ms display response time type |
300 ms maximum delay first up |
<= 1 % of the measuring range overall accuracy |
<= 0.6 % of the measuring range measurement accuracy on switching output |
+/- 03 % of measuring range/ deg C drift of the sensitivity |
+/- 0.1 % of measuring range/ deg C drift of the zero point |
<= 1 % of the measuring range display accuracy |
10000000 cycles mechanical durability |