Telemecanique XMLR010G1N26 XM Fixed Differential Electronic Pressure Transmitter Sensor, 145 psi, <=10 ms Response, Analog + NO-NC NPN Programmable/Solid State Output, 24 VDC
Pressure Sensors
PDW~11083328
MFG #: XMLR010G1N26
Telemecanique Sensors
329.00000
/ ea
Telemecanique OsiSense® XM Electronic Pressure Transmitter Sensor, Fixed Differential, Series: XMLR, 145 psi Sensing Range, <=10 ms Response, Analog + NO-NC NPN Programmable/Solid State Output, 24 VDC, 250 mA, 4-Pin M12 Male Connector x 1/4-18 FNPT, (1) Yellow LED Light Source, 580.15 psi, 1.61 in W x 1.65 in D x 3.94 in H, IP65/IP67, Environmental Conditions: -40 to 176 deg F Ambient Air Storage/-4 to 176 deg F Ambient Air Operation/50 gn Shock Resistance
- Brochure URL - d5688241de64620e1ac3824440c0596c9e43a995.pdf(Brochure URL)
- Computer~Aided [CAD|BIM] Model URL(Computer~Aided [CAD|BIM] Model URL)
- Install Instructions 1 URL - 11003_XJNCKHB127RULYQD.pdf(Install Instructions 1 URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Spec Sheet URL - 11003_VX1F0ZNYQD487UCB.pdf(Spec Sheet URL)
- Applications
- Features
PRESSURE TRANSMITTER WITH 1 SWITCHING OUTPUT |
4 DIGITS 7 SEGMENTS |
Offset compensation in the range of +/-5% of the nominal pressure |
Adjustment of analog end point between 75 and 125% of the nominal pressure |
Time delay both on trip and on reset (adjustable from 0 to 50 s, in steps of 1 s) |
Illumination of all the segments of the display on each power-up, enabling checking of their operation |
Diagnostic function for checking correct operation of the sensor |
Saving of min and max pressures measured by the sensor and their subsequent display |
Gauge ceramic pressure technology |