Schneider Electric TeSys™ F LC1F800 F-Line LC1F IEC Contactor, 600 VAC V Coil, 1000 A, 3NO Contact, 3 Poles
NEMA & IEC Contactors
529089
MFG #: LC1F800
Square D™
7684.63000
/ ea
Schneider Electric TeSys™ F IEC Contactor, F-Line LC1F, 600 VAC Coil, 1000 A Maximum Load Current, 450 kW Coil, 3 Pole, 50/60 Hz Frequency, 120/77 W Wattage, 3NO Contact Configuration, 800 A at 600 VAC Contact, Screw Clamp Connection, Bolted Terminal, IP20 Enclosure, -23 to 131 deg F Operating, Surface Mounting, 12.17 in W x 10.04 in D x 11.97 in H Dimensions
- Brochure URL - 11003_KSGYFRZ9O1J6MP3N.pdf(Brochure URL)
- Computer~Aided [CAD|BIM] Model URL(Computer~Aided [CAD|BIM] Model URL)
- Install Instructions 1 URL - 11003_WPRQF1HY3JVAKSU6.pdf(Install Instructions 1 URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Service Manual URL - 11003_3B8D4APYGK25W16M.pdf(Service Manual URL)
- Service Manual URL - 11003_4B8RSO5LX2YCKNQJ.pdf(Service Manual URL)
- Spec Sheet URL - 11003_E0RV4TXULNG3OZQ9.pdf(Spec Sheet URL)
- Spec Sheet URL - 11003_Y8FCA5EHNGMD47B2.pdf(Spec Sheet URL)
- Tech Bulletin URL - 11003_8G547S3DJIOHPNLZ.pdf(Tech Bulletin URL)
- Tech Bulletin URL - 11003_R8DPHVO6FAXJE9S2.pdf(Tech Bulletin URL)
- Tech Drawing URL(Tech Drawing URL)
- Tech Drawing URL - 11003_0IW1PUXQBNE2HSZF.dxf(Tech Drawing URL)
- Video - https://www.youtube.com/embed/GW6XwNd-Fek(Video)
- Applications
- Features
For motor control and resistive loads |
8 kV rated impulse withstand voltage |
III overvoltage category |
8000 A at 104 deg F conventional free air thermal current |
6400 A conforming to IEC 60947-4-1 rated breaking capacity |
1000 A aM at 440 V/800 A gG at 440 V associated fuse rating |
0.12 MOhm at 50 Hz to Ith 1000 A average impedance |
1000 V conforming to IEC 60947-4-1/1500 V conforming to VDE 0110 group C rated insulation voltage |
513.27 in-lb tightening torque power circuit |
100 to 170 ms closing, 40 to 65 ms opening operating time |
1100 VA at 68 deg F 40 to 400 Hz inrush power |
1100 VA at 68 deg F 40 to 400 Hz inrush power |
18 VA at 68 deg F 40 to 400 Hz hold-in power consumption |
18 W heat dissipation |
TH protective treatment |
-40 to 158 deg F permissible ambient air temperature around the device |
9842.52 ft without derating in temperature operating altitude |
Vibrations contactor closed 6 gn, 5 to 300 Hz/shocks contactor open 9 gn for 11 ms/vibrations contactor open 2 gn, 5 to 300 Hz/shocks contactor closed 15 gn for 11 ms mechanical robustness |
450 kW at 440 VAC 50/60 Hz AC-3, 450 kW at 1000 VAC 50/60 Hz AC-3, 450 kW at 500 VAC 50/60 Hz AC-3, 475 kW at 660 to 690 VAC 50/60 Hz AC-3 motor power |
110 kW at 400 VAC 50/60 Hz AC-4 450 kW at 380 to 400 VAC 50/60 Hz AC-3, 450 kW at 415 VAC 50/60 Hz AC-3, 250 kW at 220 to 240 VAC 50/60 Hz AC-3 motor power |
120 W (AC-1), 77 W (AC-3) power dissipation per pole |