Schneider Electric TPRST009 TESYS Series, 24 VDC v coil, IP20 enclosure
IEC Starters
1478822
MFG #: TPRST009
Square D™
275.74000
/ ea
Schneider Electric TPRST009, TESYS Series, 690 VAC, 9 to 15 A, 63 Hz Frequency, 2.2 kW Motor, 24 VDC Coil, Remotely/Automatically Reset, IP20 Enclosure, 30 cycles Operating Cycles, 14 to 122,122 to 140 deg F Operating, 4.57 in H x 1.77 in W x 4.53 in D Dimensions
- 360 Degree View URL - index.html?pid=11003&id=15646070360Den&ext=webp(360 Degree View URL)
- Brochure URL - 56213a69c0c281581faba51e4fa870ddbbb5170b.pdf(Brochure URL)
- Computer~Aided [CAD|BIM] Model URL(Computer~Aided [CAD|BIM] Model URL)
- Install Instructions 1 URL - 11003_QLC9HZKI17DUV6RO.pdf(Install Instructions 1 URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Service Manual URL - 11003_Y6UQ5FA1BKI0982N.pdf(Service Manual URL)
- Spec Sheet URL - 11003_OI7XW4GN08Z9M5HE.pdf(Spec Sheet URL)
- Tech Bulletin URL - 11003_LE1G2QYD6VBOP9FR.pdf(Tech Bulletin URL)
- User Manual URL - 11003_WLPKBI8XV32MGAJZ.pdf(User Manual URL)
- Features
Direct starter connected to an automation controller through a bus coupler;operational only when connected to a bus coupler;Upstream voltage presence detection;electrical line and load protection;power and energy monitoring when connected with TPRVM voltage module; for DS (device status) 1 LED (green/red); for LS (load status) 1 LED (green/red) |
The system manages motors and other electrical loads up to 40 HP |
Up to 20 modules and 1 bus coupler (up to 112cm length) |
One-click mounting on DIN rail and no need for control wiring on modules |
No auxiliary wiring required, thanks to full connectivity over fieldbus |
Digital & Analog I/Os available |
Different products complaints with international standards (IEC / UL / CSA 61010, IEC / UL / CSA 60947, GB/T14018) |
Only 20 commercial references for the complete system, including 5 standard motor starters and 5 SIL motor starters for functional safety systems as defined in IEC 61508, IEC 62061 and ISO 13849-1 |
Energy monitoring at load level |
Cybersecurity embedded into the system (Achilles Level 2) |
Open connectivity thanks to EtherNet/IP and Modbus TCP fieldbuses |
Open connectivity thanks to EtherNet/IP and Modbus TCP fieldbuses |
Direct starter connected to an automation controller through a bus couplerOperational only when connected to a bus coupler device presentation |
690 V IEC 60947-4-1 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1 ui rated insulation voltage |
6 kV IEC 60947-1 uimp rated impulse withstand voltage |
III overvoltage category |
0.18 to 9 A thermal protection adjustment range |
Class 5 to 30 thermal overload class |
Remotely or automatically reset |
210 A 104 deg F (40 deg C) - 1 s105 A 104 deg F (40 deg C) - 10 s61 A 104 deg F (40 deg C) - 1 min30 A 104 deg F (40 deg C) - 10 min icw rated short-time withstand current |