• Applications
  • Features
Oil and Gas, Mining, Minerals and Metals, Food and Beverage, Water and Wastewater, Asynchronous and Synchronous and Special Motors Applications
Constant torque standard;variable torque standard;optimized torque mode;16 preset speeds;Control screw terminal 0.5...1.5 mm² AWG 20...AWG 16;line side screw terminal 25...50 mm² AWG 4...AWG 1;motor screw terminal 25...50 mm² AWG 4...AWG 1;DC bus screw terminal 25...50 mm² AWG 4...AWG 1;1;Thermal protection motor;safe torque off motor;motor phase break motor;thermal protection drive;safe torque off drive;overheating drive;overcurrent between output phases and earth drive;overload of output voltage drive;short-circuit protection drive;motor phase break drive;overvoltages on the DC bus drive;line supply overvoltage drive;line supply undervoltage drive;line supply phase loss drive;overspeed drive;break on the control circuit drive;External supply for digital inputs 24 V DC 19-30 V), <1.25 mA overload and short-circuit protection;internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 mA overload and short-circuit protection;internal supply for digital inputs and STO 24 V DC 21-27 V), <200 mA overload and short-circuit protection
Ethernet/IP serial Modbus® TCP communication
Performance on motor control with an overload torque up to 1.8 Tn in an open or closed loop
Asynchronous, synchronous, special motors: all efficiency classes, brand independent, permanent magnet motors, torque motors, conical sliding rotor, reluctance motor
Integrated Ethernet/IP and Modbus® TCP dual port, cybersecurity (Achilles level 2)
Smart integration in PlantStruxure and Foxboro Evo process automation systems
Optimized energy efficiency, detection of energy consumption drift of the installation
Adaptation to the process by dedicated functions with modular design
Embedded safety functions STO SIL 3
Master/slave and load sharing with drive to drive capability
Torque sharing on elastic coupling
Torque sharing on elastic coupling
Contextual access to technical documentation through dynamic QR code
Continuous and historical real time measurements with customizable dashboards
Predictive maintenance
53.3 A at 380 VAC normal duty, 45.9 A at 480 VAC normal duty, 40.5 A at 380 VAC heavy duty, 35.8 A at 480 VAC heavy duty amperage rating
40 hp at normal duty, 30 hp at heavy duty horsepower rating
16 preset speeds, STO (safe torque off) SIL 3
0.5 to 1.5 sq-mm control, 25 to 50 sq-mm DC bus, 25 to 50 sq-mm line side bus, 25 to 50 sq-mm motor screw terminal
External supply for digital inputs: 24 VDC (19 to 30 V) current
Forced convection, optimized torque mode, variable torque standard, constant torque standard, motor - thermal protection, safe torque off, motor phase break, drive - thermal protection, safe torque off, overheating, overcurrent between output phases and earth, overload of output voltage, short circuit protection, motor phase break, overvoltage on the DC bus, line supply overvoltage, line supply undervoltage, line supply phase loss, overspeed, break on the control circuit