Schneider Electric ATV212WD11N4C ATV212 Series Variable Speed Drive, 380 to 480 V, 21.1 A, 15 hp, 11.42 in w x 12.40 in d
AC Variable Frequency Drives
PDW~13592614
MFG #: ATV212WD11N4C
Square D™
0.00000
/ ea
Schneider Electric ATV212WD11N4C, Variable Speed Drive, ATV212 Series, 380 to 480 V, 21.1 A, 15 hp, 11.42 in Width, 12.40 in Depth, 22.05 in Height, IP55 Enclosure
- Brochure URL - 11003_CD3082ZXYEQIWSHK.pdf(Brochure URL)
- Computer~Aided [CAD|BIM] Model URL - files?p_enDocType=CAD&p_File_Name=MCADID0000884_2D-front.dxf(Computer~Aided [CAD|BIM] Model URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Service Manual URL - 11003_1DBOTAUIE5HLQVJP.pdf(Service Manual URL)
- Service Manual URL - 11003_LJHX4F7NBV16MGYD.pdf(Service Manual URL)
- Spec Sheet URL - 11003_4CRVMF5I80SDKP1E.pdf(Spec Sheet URL)
- User Manual URL - 11003_02F759D4Y6PUNXTK.pdf(User Manual URL)
- User Manual URL - 11003_K0F4R39OPIHZUMLD.pdf(User Manual URL)
- Video - https://www.youtube.com/embed/pmcla4z86B0(Video)
- Applications
- Features
Asynchronous motors,Pumps and fans in HVAC |
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14;L1/R, L2/S, L3/T terminal 10-10 mm² / AWG 6;U/T1, V/T2, W/T3 terminal 16-16 mm² / AWG 4;Voltage/frequency ratio, 2 points;voltage/frequency ratio - Energy Saving, quadratic U/f;flux vector control without sensor, standard;voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo);voltage/frequency ratio, 5 points;Overheating protection drive;line supply undervoltage drive;against input phase loss drive;thermal protection motor;motor phase break motor;with PTC probes motor;thermal power stage drive;short-circuit between motor phases drive;input phase breaks drive;overcurrent between output phases and earth drive;overvoltages on the DC bus drive;break on the control circuit drive;against exceeding limit speed drive;line supply overvoltage and undervoltage drive;Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection;internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection |
This economical drive reduces energy costs by adjusting motor speed to the required flow of air or fluids |
It can also lower your installation costs by eliminating throttling values, dampers or inlet guide vanes typically used to control flow in HVAC applications |
In addition, building occupant comfort is efficiently controlled as heating and cooling demand loads vary |
Small size saves valuable panel space |
Includes a full complement of integrated building automation networks |
Optional remote mount English text keypad speeds troubleshooting |
Reduced harmonic technology eliminates the need for line reactors and reduces both wire size and upstream overcurrent protection devices, further saving panel space and lowering component cost |
Class C1 EMC filter integrated emc filter |
BACnetMETASYS N2LonWorksModbusAPOGEE FLN communication port protocol |
With heat sink assembly style |
With heat sink assembly style |
17.1 kVA 380 V apparent power |
22 kA prospective line isc |
22.5 A 380 V22.5 A 460 V continuous output current |
0.5 to 200 Hz speed drive output frequency |
1 to 10 speed range |
+/- 10 % of nominal slip 0.2 Tn to Tn speed accuracy |
+/- 15 % torque accuracy |
120 % of nominal motor torque +/- 10 % 60 s transient overtorque |