Burndy® YCHC29TC2 CRIMPIT™ YCHC C-Tap Compression Connector, C Shape, 2 AWG to 250 kcmil Main/Run Size, 6 to 2 AWG Tap Size

Compression C-Taps
366983 MFG #: YCHC29TC2
BURNDY®
32.15000 / ea
BURNDY® CRIMPIT™ C-Tap Compression Connector, Series: YCHC, C, 2 AWG to 250 kcmil Main/Run Size, 6 to 2 AWG Tap, Commercial Stranded/Flexible Copper Conductor, 997 Element A Die Index, Red Color Code 1 in Wire Stripe, 90 deg C, Copper, Electro-Plated Tin, 0.81 in L x 0.97 in W x 1.78 in H
QTY
  • Applications
  • Features
Wire Tap
Features: Wide Range Of Run/Tap Combinations Including Class B Code I And Locomotive Flexible Conductor Combinations, All (B/B, B/I, I/I) Combinations Are Recommended: Each Connector Accommodates Many Cable Combinations, Allowing Maximum Flexibility For The Design And Installation Of A System, Color-Coded On The Connector That Matches The Die: Provides Matched System For Fast And Easy Installation, Each Connector Has A Recommended Insulating Cover Available, Flame Retardant Type CF-FR Covers Meet Oxygen Index 28 And UL94 V-O Requirements: A Complete Insulated UL Listed Installation Is Provided, Die Index Embossed On Connector After Completion Of Crimp: Permanent Inspectability Of Installed Connector Is Insure Consistently Reliable And Dependable Connections, Use PUADP-1 Adaptor With U Dies In Y46, Color Code: Red, Flame Retardant Cover: CFD-FR, Die Index: 997 Element A, Shape: C, Tools, Die Set Catalog Number, And (number Of Crimps): Y750 Tool, U251 Die, (1), Y46 Tool, U251 Die With PUADP-1 Adapter, (1), Wire Strip Length: 1 IN
Wide range of run/tap combinations including class B code I and locomotive flexible conductor combinations, all All (B/B, B/I, I/I) combinations are recommended
Each connector accommodates many cable combinations, allowing maximum flexibility for the design and installation of a system
Color coded on the connector that matches the die provides matched system for fast and easy installation
Each connector has a recommended insulating cover available, flame retardant type CF-FR covers meet oxygen index 28 and UL94 V-O requirements
Die index embossed on connector after completion of crimp, permanent inspectability of installed connector is insure consistently reliable and dependable connections
Use PUADP-1 adaptor with U dies in Y46, tools, die set catalog number, and (number of crimps) Y750 tool, U251 die, (1), Y46 tool, U251 die with PUADP-1 adapter, (1), flame retardant cover CFD-FR
250 kcmil - 2 AWG (main), 2 - 6 AWG (tap 1), 8 - 14 AWG (tap 2)
Commercial copper 250 kcmil - 2 AWG, flex copper 4/0 - 2 AWG tap size
Commercial copper 250 kcmil - 2 AWG, flex copper 4/0 - 2 AWG run size