or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Appleton™
Appleton® EYF50-AL Unilet® EY Series Explosionproof Conduit Sealing Fitting, 1/2 in, Almag 35 Aluminum, Epoxy Powder Coated
Custom_Product_Images_Illustration
Appleton™
Appleton® EYF50-AL Unilet® EY Series Explosionproof Conduit Sealing Fitting, 1/2 in, Almag 35 Aluminum, Epoxy Powder Coated
SKU397983
MFGR #EYF50AL
Your Cost: $34.09/ea
These sealing fittings minimizes the passage of gases and vapors and prevents the passage of flames from oneportion of a conduit system to another. they prevent pressure piling the within conduit system and contain any explosion that occurs. The EY series is a close radius type for sealing vertical or horizontal conduit runs.
These sealing fittings minimizes the passage of gases and vapors and prevents the passage of flames from oneportion of a conduit system to another. they prevent pressure piling the within conduit system and contain any explosion that occurs. The EY series is a close radius type for sealing vertical or horizontal conduit runs.
Application For Use With Threaded Rigid Metal Conduit And IMC ARRA Compliant N Buy American Compliant N Catalog Number EYF50AL Connection Female Threaded Country of Origin MX Currency USD Dimensions 3.5 in L x 1.19 in W EU RoHS Indicator C Gross Weight Per Pack 0.2200 lb Gross Weight per Pack Metric 0.11 Gross Weight UOM Metric kg Height 0.68 in Height [Metric] 17.2720 mm Length 5.60 in Length [Metric] 14.2240 cm Series EY Series Standard UL 886 (1203), UL File Number E10444, CSA C22.2 No. 30, CSA 065181, UL Listed For Class I, Groups A, B, C, D; Class II, Groups E, F, G; And Class III Standards UL 886UL 1203UL File No. E10444CSA C22.2 No. 30CSA 065181Class I, Groups A, B, C, D, Class II, Groups E, F, G, Class IIIRoHS Compliant Sub Brand UNILETS Type Dust-Ignitionproof Explosionproof Raintight UNSPSC 39121311 UPC 11 78138159997 UPC 12 781381599979 Width 5.20 in Width [Metric] 13.2080 cm Stock Status NONSTOCK Brand Appleton™ Manufacturer Appleton Finish Epoxy Powder Coated Material Almag 35 Aluminum Size 1/2 in Suitable For Use With IMC/Threaded Rigid Metallic Conduit For Use With Threaded Rigid Metal Conduit and IMC For preventing passage of gases, vapors or flames from one portion of conduit system to another; Required in Class I, Division 1 and 2 locations where 2 IN or larger conduit enters enclosure, fitting housing terminals, splices or taps; Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location; Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 IN or less conduit, seal must be located within 18 IN of either enclosure; Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in Class I, Division 2 locations; Explosionproof, dust-ignitionproof, raintight; Smooth, rounded integral bushing in each hub protects conductor insulation; Accurately tapped, tapered threads for tight, rigid joints and ground continuity; Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub; Close radius type for sealing vertical or horizontal con Smooth, rounded integral bushing in each hub to protect conductor insulation Accurately tapped, tapered NPT threads for tight, rigid joints and ground continuity Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub Restrict any explosion to the sealed off enclosure Required in Class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures Required in Class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure Required where cables which exceed rate of gas or vapor transmission permitted for seals are used in Class I, Division 2 locations 25% fill vertical and horizontal conduit sealing fittings for close turning radius Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in class I, Division 2locations 1.06 in turning radius Female threaded connection 25% fill vertical and horizontal conduit sealing fittings for close turning radius
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Application | For Use With Threaded Rigid Metal Conduit And IMC |
| ARRA Compliant | N |
| Buy American Compliant | N |
| Catalog Number | EYF50AL |
| Connection | Female Threaded |
| Country of Origin | MX |
| Currency | USD |
| Dimensions | 3.5 in L x 1.19 in W |
| EU RoHS Indicator | C |
| Gross Weight Per Pack | 0.2200 lb |
| Gross Weight per Pack Metric | 0.11 |
| Gross Weight UOM Metric | kg |
| Height | 0.68 in |
| Height [Metric] | 17.2720 mm |
| Length | 5.60 in |
| Length [Metric] | 14.2240 cm |
| Series | EY Series |
| Standard | UL 886 (1203), UL File Number E10444, CSA C22.2 No. 30, CSA 065181, UL Listed For Class I, Groups A, B, C, D; Class II, Groups E, F, G; And Class III |
| Standards | UL 886UL 1203UL File No. E10444CSA C22.2 No. 30CSA 065181Class I, Groups A, B, C, D, Class II, Groups E, F, G, Class IIIRoHS Compliant |
| Sub Brand | UNILETS |
| Type | Dust-Ignitionproof Explosionproof Raintight |
| UNSPSC | 39121311 |
| UPC 11 | 78138159997 |
| UPC 12 | 781381599979 |
| Width | 5.20 in |
| Width [Metric] | 13.2080 cm |
| Stock Status | NONSTOCK |
| Brand | Appleton™ |
| Manufacturer | Appleton |
| Finish | Epoxy Powder Coated |
| Material | Almag 35 Aluminum |
| Size | 1/2 in |
| Suitable For Use With | IMC/Threaded Rigid Metallic Conduit |
| For Use With Threaded Rigid Metal Conduit and IMC |
| For preventing passage of gases, vapors or flames from one portion of conduit system to another; Required in Class I, Division 1 and 2 locations where 2 IN or larger conduit enters enclosure, fitting housing terminals, splices or taps; Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location; Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 IN or less conduit, seal must be located within 18 IN of either enclosure; Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in Class I, Division 2 locations; Explosionproof, dust-ignitionproof, raintight; Smooth, rounded integral bushing in each hub protects conductor insulation; Accurately tapped, tapered threads for tight, rigid joints and ground continuity; Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub; Close radius type for sealing vertical or horizontal con |
| Smooth, rounded integral bushing in each hub to protect conductor insulation |
| Accurately tapped, tapered NPT threads for tight, rigid joints and ground continuity |
| Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub |
| Restrict any explosion to the sealed off enclosure |
| Required in Class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures |
| Required in Class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps |
| Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location |
| Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure |
| Required where cables which exceed rate of gas or vapor transmission permitted for seals are used in Class I, Division 2 locations |
| 25% fill vertical and horizontal conduit sealing fittings for close turning radius |
| Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in class I, Division 2locations |
| 1.06 in turning radius |
| Female threaded connection |
| 25% fill vertical and horizontal conduit sealing fittings for close turning radius |