Appleton® EYD86 Unilet® EYD Explosionproof Conduit Sealing Fitting With Removable Male Nipple, 3 in, Grayloy-Iron, Tri-Coated
Custom_Product_Images_Illustration
Appleton® EYD86 Unilet® EYD Explosionproof Conduit Sealing Fitting With Removable Male Nipple, 3 in, Grayloy-Iron, Tri-Coated
SKU936458
MFGR #EYD86
Your Cost: $429.32/ea
These Appleton sealing fittings minimizes the passage of gases and vapors and prevents the passage of flames from one portion of a conduit system to another. They prevent pressure piling the within conduit system and contain any explosion that occurs.
These Appleton sealing fittings minimizes the passage of gases and vapors and prevents the passage of flames from one portion of a conduit system to another. They prevent pressure piling the within conduit system and contain any explosion that occurs.
Application For Use With Threaded Rigid Metal Conduit and IMC ARRA Compliant N Buy American Compliant N Catalog Number EYD86 Color Gray Connection Tapered MNPT X Tapered FNPT Country of Origin MX Currency USD Dimensions 8-1/2 in L x 4-1/4 in W EU RoHS Indicator C Gross Weight Per Pack 11.4200 lb Gross Weight per Pack Metric 5.18 Gross Weight UOM Metric kg Height 6.00 in Height [Metric] 15.2400 cm Length 11.00 in Length [Metric] 27.9400 cm Series EYD Standard UL 886 (1203), UL File Number E10444, CSA C22.2 No. 30, CSA 065181, UL Listed For Class I, Division 1 And 2 Groups C, D, Class II, Division 1 And 2 Groups E, F, G, Class III Standards UL 886UL 1203UL File No. E10444CSA C22.2 No. 30CSA 065181Class I, Div 1 and 2, Groups C, D, Class II, Div 1 and 2, Groups E, F, G, Class IIIRoHs Compliant Sub Brand UNILETS Type Dust-Ignitionproof Explosionproof Raintight UNSPSC 39121311 UPC 11 78138162096 UPC 12 781381620963 Width 6.00 in Width [Metric] 15.2400 cm Stock Status NONSTOCK Brand Appleton™ Manufacturer Appleton Finish Zinc Electroplate/Chromate/Epoxy Powder Coat Material Grayloy-Iron Size 3 in Suitable For Use With IMC/Threaded Rigid Metallic Conduit For Use With Threaded Rigid Metal Conduit and IMC For preventing passage of gases, vapors or flames from one portion of conduit system to another; Required in Class I, Division 1 and 2 locations within 18 IN of enclosures containing apparatus that may cause arcs, sparks or high temperatures; Required in Class I, Division 1 and 2 locations where 2 IN or larger conduit enters enclosure, fitting housing terminals, splices or taps; Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location; Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 IN or less conduit, seal must be located within 18 IN of either enclosure; Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in Class I, Division 2 locations; Explosionproof, dust-ignitionproof, raintight; Smooth, rounded integral bushing in each hub protects conductor insulation; Accurately tapped, tapered threads for tight, rigid joints and ground continuity; U Smooth, rounded integral bushing in each hub protects conductor insulation Accurately tapped, tapered threads for tight, rigid joints and ground continuity Dust-ignition proof, raintight Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub Close radius type for sealing vertical conduit runs Restrict any explosion to the sealed off enclosure Required in class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures Required in class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps Required in class I, Division 1 and 2 locations at the boundary where conduit leaves classified location Required in class I, Division 1 and 2 locations where two or more enclosures are connected by 36 or less conduit, seal must be located within 18 in of either enclosure Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in class I, Division 2locations 3.13 in turning radius Tapered MNPT X tapered FNPT connection 25% fill vertical conduit drain sealing fittings Triple-Coat (Zinc Electroplate, Chromate And epoxy Powder Coat) finish Access cover has drain valve for automatic draining of water accumulation above the sea
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| Application | For Use With Threaded Rigid Metal Conduit and IMC |
| ARRA Compliant | N |
| Buy American Compliant | N |
| Catalog Number | EYD86 |
| Color | Gray |
| Connection | Tapered MNPT X Tapered FNPT |
| Country of Origin | MX |
| Currency | USD |
| Dimensions | 8-1/2 in L x 4-1/4 in W |
| EU RoHS Indicator | C |
| Gross Weight Per Pack | 11.4200 lb |
| Gross Weight per Pack Metric | 5.18 |
| Gross Weight UOM Metric | kg |
| Height | 6.00 in |
| Height [Metric] | 15.2400 cm |
| Length | 11.00 in |
| Length [Metric] | 27.9400 cm |
| Series | EYD |
| Standard | UL 886 (1203), UL File Number E10444, CSA C22.2 No. 30, CSA 065181, UL Listed For Class I, Division 1 And 2 Groups C, D, Class II, Division 1 And 2 Groups E, F, G, Class III |
| Standards | UL 886UL 1203UL File No. E10444CSA C22.2 No. 30CSA 065181Class I, Div 1 and 2, Groups C, D, Class II, Div 1 and 2, Groups E, F, G, Class IIIRoHs Compliant |
| Sub Brand | UNILETS |
| Type | Dust-Ignitionproof Explosionproof Raintight |
| UNSPSC | 39121311 |
| UPC 11 | 78138162096 |
| UPC 12 | 781381620963 |
| Width | 6.00 in |
| Width [Metric] | 15.2400 cm |
| Stock Status | NONSTOCK |
| Brand | Appleton™ |
| Manufacturer | Appleton |
| Finish | Zinc Electroplate/Chromate/Epoxy Powder Coat |
| Material | Grayloy-Iron |
| Size | 3 in |
| Suitable For Use With | IMC/Threaded Rigid Metallic Conduit |
| For Use With Threaded Rigid Metal Conduit and IMC |
| For preventing passage of gases, vapors or flames from one portion of conduit system to another; Required in Class I, Division 1 and 2 locations within 18 IN of enclosures containing apparatus that may cause arcs, sparks or high temperatures; Required in Class I, Division 1 and 2 locations where 2 IN or larger conduit enters enclosure, fitting housing terminals, splices or taps; Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location; Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 IN or less conduit, seal must be located within 18 IN of either enclosure; Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in Class I, Division 2 locations; Explosionproof, dust-ignitionproof, raintight; Smooth, rounded integral bushing in each hub protects conductor insulation; Accurately tapped, tapered threads for tight, rigid joints and ground continuity; U |
| Smooth, rounded integral bushing in each hub protects conductor insulation |
| Accurately tapped, tapered threads for tight, rigid joints and ground continuity |
| Dust-ignition proof, raintight |
| Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub |
| Close radius type for sealing vertical conduit runs |
| Restrict any explosion to the sealed off enclosure |
| Required in class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures |
| Required in class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps |
| Required in class I, Division 1 and 2 locations at the boundary where conduit leaves classified location |
| Required in class I, Division 1 and 2 locations where two or more enclosures are connected by 36 or less conduit, seal must be located within 18 in of either enclosure |
| Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in class I, Division 2locations |
| 3.13 in turning radius |
| Tapered MNPT X tapered FNPT connection |
| 25% fill vertical conduit drain sealing fittings |
| Triple-Coat (Zinc Electroplate, Chromate And epoxy Powder Coat) finish |
| Access cover has drain valve for automatic draining of water accumulation above the sea |