Fluke® FLUKE-355 355 Clamp Meter, 600 VAC/1000 VDC, 1400 A AC/2000 A DC, 400 kOhm, 5 Hz to 1 kHz, 2.3 in Jaw, Backlight Display
Clamp Meters
409504
MFG #: FLUKE-355
Fluke®
1139.99000
/ ea
- AC Current Accuracy: 1.5% + 5 Digits
- Alternate Catalog Number: 2840265
- Amperage Rating: 1.4k/2k A
- Application: For Utilities, Electrical Contractors And Industrial Service Technicians
- ARRA Compliant: C
- Battery: (6) 1.5 V AA NEDA 15 AMP Or IEC LR6
- Buy American Compliant: C
- Catalog Number: FLUKE-355
- Country of Origin: CN
- Currency: USD
- Dimensions: 12 IN Length
- Enclosure: IP42
- EU RoHS Indicator: U
- Gross Weight Per Pack: 1.8000 lb
- Gross Weight per Pack Metric: 0.82
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 9030310000
- Height: 2.00 in
- Height [Metric]: 5.0800 cm
- Length: 12.00 in
- Length [Metric]: 30.4800 cm
- Model: 355
- Operating Temperature: 32 to 122 °F
- Power Source: (6) 1.5 VDC AA NEDA 15 A Battery
- Safety Rating: CAT IV 600 VAC/CAT III 1000 VAC/IP42
- Standard: CE Certified, C/US CSA Certified, N10140 Confirmed, CAT IV 600 V, CAT III 1000 V, IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III EMI, RFI, EMC: FCC Part 15, IEC/EN 61326-1:1997 Class B IEC/EN 61326:1997 3 V/M, Performance Criteria B, EN61325
- Temperature Rating: 32 to 122 °F
- Type: Digital Clamp Meter
- UNSPSC: 41113630
- UPC 11: 09596940120
- UPC 12: 095969401203
- Voltage Accuracy: 3% Reading + 5 Digits
- Voltage Rating: 1,414k//1,000 VAC//VDC
- Width: 3.75 in
- Width [Metric]: 9.5250 cm
- Stock Status: NONSTOCK
- Brand: Fluke®
- Manufacturer: Fluke Corporation
- Display Type: Backlit
- Electrical Ratings: 600 VAC, 1000 VDC, 1400 A AC, 2000 A DC
- Frequency Rating: 5 Hz to 1 kHz
- Jaw Capacity: 2.3 in
- Resistance: 4/40/400 KOHM
Confidently take reliable readings with the true-rms, Fluke 355/353 Clamp Meters; the tools of choice for high-current measurements up to 2000 A. The extra-wide jaw easily clamps around large conductors typically found in highcurrent applications. The rugged design and CAT IV 600 V, CAT III 1000 V ratings, add an extra element of protection when taking high-powered measurements.
- http://www.fluke.com(Seller Home Page URL)
- http://www.fluke.com/(Seller Home Page URL)
- Spec Sheet URL - 11095_6V4MEPUOXRK039T8.pdf(Spec Sheet URL)
- Owners Manual URL - F-merch_57a_h(Owners Manual URL)
- Owners Manual URL - 11095_ONZ62TVPEBU4YJD5.jpg(Owners Manual URL)
- Spec Sheet URL - 3094045_6115_ENG_A_W.PDF(Spec Sheet URL)
- Warranty URL - 11095_WAR_FLUKE_Warranties_2014.pdf(Warranty URL)
- Video - https://www.youtube.com/embed/aRJMNqffdlc(Video)
- Applications
- Features
For Utilities, Electrical Contractors And Industrial Service Technicians |
The tools of choice for high current clamp-on amp meter measurement up to 2000 AMP; The extra-wide jaw easily clamps around large conductors, typically found in high-current applications; The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements; Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads; The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians; Reliably handle a wide range of high-current applications with 2000 AMP AC plus DC true-rms, 1400 AMP AC and 2000 AMP DC; The large 58 MM jaw capacity is suitable for large or multiple conductors; CAT IV 600 V, CAT III 1000 V rating for added user protection; In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability; High voltage measurement of 1000 VAC plus VDC true-rms, 600 VAC and 1000 VDC allows the user to perform multiple tests with only one tool (355 only); Resistance to 400 KOHM coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter (355 only); Accurately measure frequency up to 1 KHZ for optimum troubleshooting; Quickly analyze readings using the minimum, maximum and average functions; A large backlit display allows for easy visibility in low-lit areas; Use the display hold feature to capture readings even when the display cannot be viewed; Use the low-pass filter to smooth out noisy loads and stabilize readings; Jaw capacity: 2-5/16 IN; Battery type: AA; AC response: TRMS; Audible continuity; Auto ranging; Data hold; Inrush and auto power off; Operating humidity: 0 - 95 PCT (non-condensing); Altitude: 2000 MR (operating ) and 10000 MR (Storage ); Drop test requirements 1 M; Temperature coefficients: 0.1 PCT of reading per DEG C outside 22 - 24 DEG C (current), 0.1 PCT of reading per DEG C outside 22 - 24 DEG C (voltage); Battery life (with typical usage, backlight off): 100 HR; Test leads rated to 1000 V; Weight: 1.8 LB; Jaw size: 58 MM; 3.75 IN Width X 2 IN Depth |
Reliably handle a wide range of high current applications with 2000 A AC + DC True-RMS, 1400 A AC and 2000 A DC |
Selectable low-pass filter mode |
Large display with backlight |
Inrush current measurement |
Versatile, professional and accurate |
IP42 IP, (6) 1.5 V AA NEDA 15 A or IEC LR6 battery, 10/100/1000 mA resolution, -4 to 140 deg F storage temperature, 1 m drop test requirements |
AC/DC current range 40 A with accuracy of (1.5 % Reading + 15 Digits) at 10 to 100 Hz and 10 mA resolution, 400 A with accuracy of (1.5 % Reading + 5 Digits) at 10 to 100 Hz and 100 mA resolution, 2000 A, 1400 A AC RMS with accuracy of (1.5 % Reading + 5 Digits) at 10 to 100 Hz and 1 A resolution, AC current range 40 A with accuracy of (3.5 % Reading + 15 Digits) at 100.1 to 1 kHz and 10 mA resolution, 400 A with accuracy of (3.5 % Reading + 5 Digits) at 100.1 to 1 kHz and 100 mA resolution, 2000 A, 1400 A AC RMS with accuracy of (3.5 % Reading + 5 Digits) at 100.1 to 1 kHz and 1 A resolution |
Resistance range 400 Ohm with accuracy of (1.5% + 5 Digit) and 0.1 Ohm resolution, 4 kOhm with accuracy of (1.5% + 5 Digit) and 1 Ohm resolution, 40 kOhm with accuracy of (1.5% + 5 Digit) and 10 Ohm resolution, 400 kOhm with accuracy of (1.5% + 5 Digit) and 100 Ohm resolution |
AC voltage range 4 V with accuracy of (1% Reading + 10 Digits) at 10 to 100 Hz and 1 mV resolution, 40 V with accuracy of (1% Reading + 5 Digits) at 10 to 100 Hz and 10 mV resolution, 400 V with accuracy of (1% Reading + 5 Digits) at 10 to 100 Hz and 100 mV resolution, 600 VAC RMS with accuracy of (1% Reading + 5 Digits) at 10 to 100 Hz and 10 mV resolution, 4 V with accuracy of (3% Reading + 10 Digits) at 100.1 to 1 kHz and 1 mV resolution, 40 V with accuracy of (3% Reading + 5 Digits) at 100.1 to 1 kHz and 10 mV resolution, 400 V with accuracy of (3% Reading + 5 Digits) at 100.1 to 1 kHz and 100 mV resolution, 600 VAC RMS with accuracy of (3% Reading + 5 Digits) at 100.1 to 1 kHz and 10 mV resolution |
Continuity beeper ON at <= 30 Ohm, off at >= 100 Ohm |
The tools of choice for high current clamp-on amp meter measurement up to 2000 A |
The extra wide jaw easily clamps around large conductors, typically found in high current applications |
The extra rugged design and Cat IV 600 V, Cat III 1000 V ratings add an extra element of user protection when taking high-powered measurements |
Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads |
The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians |
The large 58 MM jaw capacity is suitable for large or multiple conductors |
Cat IV 600 VAC, Cat III 1000 VAC rating for added user protection |
In-rush current measurement captures power-on™ surge current with accuracy and repeatability |
High voltage measurement of 1000 VAC plus VDC True-RMS, 600 VAC and 1000 VDC allows the user to perform multiple tests with only one tool (355 only |
Resistance to 400 kOhm coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter (355 only |