or to view stock quantity and your pricing.
Steiner serves territories in Northern Illinois, Northwest Indiana and Southern Wisconsin. Please for assistance if outside our sales territory.
Fluke®
Fluke® FLUKE-355 355 Clamp Meter, 600 VAC/1000 VDC, 1400 A AC/2000 A DC, 400 kOhm, 5 Hz to 1 kHz, 2.3 in Jaw, Backlight Display
Custom_Product_Images_Illustration
Fluke®
Fluke® FLUKE-355 355 Clamp Meter, 600 VAC/1000 VDC, 1400 A AC/2000 A DC, 400 kOhm, 5 Hz to 1 kHz, 2.3 in Jaw, Backlight Display
SKU409504
MFGR #FLUKE-355
Your Cost: $1,248.99/ea
Confidently take reliable readings with the true-rms, Fluke 355/353 Clamp Meters; the tools of choice for high-current measurements up to 2000 A. The extra-wide jaw easily clamps around large conductors typically found in highcurrent applications. The rugged design and CAT IV 600 V, CAT III 1000 V ratings, add an extra element of protection when taking high-powered measurements.
Confidently take reliable readings with the true-rms, Fluke 355/353 Clamp Meters; the tools of choice for high-current measurements up to 2000 A. The extra-wide jaw easily clamps around large conductors typically found in highcurrent applications. The rugged design and CAT IV 600 V, CAT III 1000 V ratings, add an extra element of protection when taking high-powered measurements.
AC Current Accuracy 1.5% + 5 Digits Alternate Catalog Number 2840265 Amperage Rating 1.4k/2k A Application For Utilities, Electrical Contractors And Industrial Service Technicians ARRA Compliant C Battery (6) 1.5 V AA NEDA 15 AMP Or IEC LR6 Buy American Compliant C Catalog Number FLUKE-355 Country of Origin CN Currency USD Dimensions 12 IN Length Enclosure IP42 EU RoHS Indicator U Gross Weight Per Pack 1.8000 lb Gross Weight per Pack Metric 0.82 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 9030310000 Height 2.00 in Height [Metric] 5.0800 cm Length 12.00 in Length [Metric] 30.4800 cm Model 355 Operating Temperature 32 to 122 °F Power Source (6) 1.5 VDC AA NEDA 15 A Battery Safety Rating CAT IV 600 VAC/CAT III 1000 VAC/IP42 Standard CE Certified, C/US CSA Certified, N10140 Confirmed, CAT IV 600 V, CAT III 1000 V, IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III EMI, RFI, EMC: FCC Part 15, IEC/EN 61326-1:1997 Class B IEC/EN 61326:1997 3 V/M, Performance Criteria B, EN61325 Temperature Rating 32 to 122 °F Type Digital Clamp Meter UNSPSC 41113630 UPC 11 09596940120 UPC 12 095969401203 Voltage Accuracy 3% Reading + 5 Digits Voltage Rating 1,414k//1,000 VAC//VDC Width 3.75 in Width [Metric] 9.5250 cm Stock Status NONSTOCK Brand Fluke® Manufacturer Fluke Corporation Display Type Backlit Electrical Ratings 600 VAC, 1000 VDC, 1400 A AC, 2000 A DC Frequency Rating 5 Hz to 1 kHz Jaw Capacity 2.3 in Resistance 4/40/400 KOHM For Utilities, Electrical Contractors And Industrial Service Technicians The tools of choice for high current clamp-on amp meter measurement up to 2000 AMP; The extra-wide jaw easily clamps around large conductors, typically found in high-current applications; The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements; Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads; The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians; Reliably handle a wide range of high-current applications with 2000 AMP AC plus DC true-rms, 1400 AMP AC and 2000 AMP DC; The large 58 MM jaw capacity is suitable for large or multiple conductors; CAT IV 600 V, CAT III 1000 V rating for added user protection; In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability; High voltage measurement of 1000 VAC plus VDC true-rms, 600 VAC and 1000 VDC allows the user to perform multiple tests with only one tool (355 only); Resistance to 400 KOHM coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter (355 only); Accurately measure frequency up to 1 KHZ for optimum troubleshooting; Quickly analyze readings using the minimum, maximum and average functions; A large backlit display allows for easy visibility in low-lit areas; Use the display hold feature to capture readings even when the display cannot be viewed; Use the low-pass filter to smooth out noisy loads and stabilize readings; Jaw capacity: 2-5/16 IN; Battery type: AA; AC response: TRMS; Audible continuity; Auto ranging; Data hold; Inrush and auto power off; Operating humidity: 0 - 95 PCT (non-condensing); Altitude: 2000 MR (operating ) and 10000 MR (Storage ); Drop test requirements 1 M; Temperature coefficients: 0.1 PCT of reading per DEG C outside 22 - 24 DEG C (current), 0.1 PCT of reading per DEG C outside 22 - 24 DEG C (voltage); Battery life (with typical usage, backlight off): 100 HR; Test leads rated to 1000 V; Weight: 1.8 LB; Jaw size: 58 MM; 3.75 IN Width X 2 IN Depth Reliably handle a wide range of high current applications with 2000 A AC + DC True-RMS, 1400 A AC and 2000 A DC Selectable low-pass filter mode Large display with backlight Inrush current measurement Versatile, professional and accurate IP42 IP, (6) 1.5 V AA NEDA 15 A or IEC LR6 battery, 10/100/1000 mA resolution, -4 to 140 deg F storage temperature, 1 m drop test requirements AC/DC current range 40 A with accuracy of (1.5 % Reading + 15 Digits) at 10 to 100 Hz and 10 mA resolution, 400 A with accuracy of (1.5 % Reading + 5 Digits) at 10 to 100 Hz and 100 mA resolution, 2000 A, 1400 A AC RMS with accuracy of (1.5 % Reading + 5 Digits) at 10 to 100 Hz and 1 A resolution, AC current range 40 A with accuracy of (3.5 % Reading + 15 Digits) at 100.1 to 1 kHz and 10 mA resolution, 400 A with accuracy of (3.5 % Reading + 5 Digits) at 100.1 to 1 kHz and 100 mA resolution, 2000 A, 1400 A AC RMS with accuracy of (3.5 % Reading + 5 Digits) at 100.1 to 1 kHz and 1 A resolution Resistance range 400 Ohm with accuracy of (1.5% + 5 Digit) and 0.1 Ohm resolution, 4 kOhm with accuracy of (1.5% + 5 Digit) and 1 Ohm resolution, 40 kOhm with accuracy of (1.5% + 5 Digit) and 10 Ohm resolution, 400 kOhm with accuracy of (1.5% + 5 Digit) and 100 Ohm resolution AC voltage range 4 V with accuracy of (1% Reading + 10 Digits) at 10 to 100 Hz and 1 mV resolution, 40 V with accuracy of (1% Reading + 5 Digits) at 10 to 100 Hz and 10 mV resolution, 400 V with accuracy of (1% Reading + 5 Digits) at 10 to 100 Hz and 100 mV resolution, 600 VAC RMS with accuracy of (1% Reading + 5 Digits) at 10 to 100 Hz and 10 mV resolution, 4 V with accuracy of (3% Reading + 10 Digits) at 100.1 to 1 kHz and 1 mV resolution, 40 V with accuracy of (3% Reading + 5 Digits) at 100.1 to 1 kHz and 10 mV resolution, 400 V with accuracy of (3% Reading + 5 Digits) at 100.1 to 1 kHz and 100 mV resolution, 600 VAC RMS with accuracy of (3% Reading + 5 Digits) at 100.1 to 1 kHz and 10 mV resolution Continuity beeper ON at <= 30 Ohm, off at >= 100 Ohm The tools of choice for high current clamp-on amp meter measurement up to 2000 A The extra wide jaw easily clamps around large conductors, typically found in high current applications The extra rugged design and Cat IV 600 V, Cat III 1000 V ratings add an extra element of user protection when taking high-powered measurements Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians The large 58 MM jaw capacity is suitable for large or multiple conductors Cat IV 600 VAC, Cat III 1000 VAC rating for added user protection In-rush current measurement captures power-on™ surge current with accuracy and repeatability High voltage measurement of 1000 VAC plus VDC True-RMS, 600 VAC and 1000 VDC allows the user to perform multiple tests with only one tool (355 only Resistance to 400 kOhm coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter (355 only
content loaded
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Applications
- Features
- Substitute Products
| AC Current Accuracy | 1.5% + 5 Digits |
| Alternate Catalog Number | 2840265 |
| Amperage Rating | 1.4k/2k A |
| Application | For Utilities, Electrical Contractors And Industrial Service Technicians |
| ARRA Compliant | C |
| Battery | (6) 1.5 V AA NEDA 15 AMP Or IEC LR6 |
| Buy American Compliant | C |
| Catalog Number | FLUKE-355 |
| Country of Origin | CN |
| Currency | USD |
| Dimensions | 12 IN Length |
| Enclosure | IP42 |
| EU RoHS Indicator | U |
| Gross Weight Per Pack | 1.8000 lb |
| Gross Weight per Pack Metric | 0.82 |
| Gross Weight UOM Metric | kg |
| Harmonization Tariff Schedule Code | 9030310000 |
| Height | 2.00 in |
| Height [Metric] | 5.0800 cm |
| Length | 12.00 in |
| Length [Metric] | 30.4800 cm |
| Model | 355 |
| Operating Temperature | 32 to 122 °F |
| Power Source | (6) 1.5 VDC AA NEDA 15 A Battery |
| Safety Rating | CAT IV 600 VAC/CAT III 1000 VAC/IP42 |
| Standard | CE Certified, C/US CSA Certified, N10140 Confirmed, CAT IV 600 V, CAT III 1000 V, IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III EMI, RFI, EMC: FCC Part 15, IEC/EN 61326-1:1997 Class B IEC/EN 61326:1997 3 V/M, Performance Criteria B, EN61325 |
| Temperature Rating | 32 to 122 °F |
| Type | Digital Clamp Meter |
| UNSPSC | 41113630 |
| UPC 11 | 09596940120 |
| UPC 12 | 095969401203 |
| Voltage Accuracy | 3% Reading + 5 Digits |
| Voltage Rating | 1,414k//1,000 VAC//VDC |
| Width | 3.75 in |
| Width [Metric] | 9.5250 cm |
| Stock Status | NONSTOCK |
| Brand | Fluke® |
| Manufacturer | Fluke Corporation |
| Display Type | Backlit |
| Electrical Ratings | 600 VAC, 1000 VDC, 1400 A AC, 2000 A DC |
| Frequency Rating | 5 Hz to 1 kHz |
| Jaw Capacity | 2.3 in |
| Resistance | 4/40/400 KOHM |
| For Utilities, Electrical Contractors And Industrial Service Technicians |
| The tools of choice for high current clamp-on amp meter measurement up to 2000 AMP; The extra-wide jaw easily clamps around large conductors, typically found in high-current applications; The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements; Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads; The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians; Reliably handle a wide range of high-current applications with 2000 AMP AC plus DC true-rms, 1400 AMP AC and 2000 AMP DC; The large 58 MM jaw capacity is suitable for large or multiple conductors; CAT IV 600 V, CAT III 1000 V rating for added user protection; In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability; High voltage measurement of 1000 VAC plus VDC true-rms, 600 VAC and 1000 VDC allows the user to perform multiple tests with only one tool (355 only); Resistance to 400 KOHM coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter (355 only); Accurately measure frequency up to 1 KHZ for optimum troubleshooting; Quickly analyze readings using the minimum, maximum and average functions; A large backlit display allows for easy visibility in low-lit areas; Use the display hold feature to capture readings even when the display cannot be viewed; Use the low-pass filter to smooth out noisy loads and stabilize readings; Jaw capacity: 2-5/16 IN; Battery type: AA; AC response: TRMS; Audible continuity; Auto ranging; Data hold; Inrush and auto power off; Operating humidity: 0 - 95 PCT (non-condensing); Altitude: 2000 MR (operating ) and 10000 MR (Storage ); Drop test requirements 1 M; Temperature coefficients: 0.1 PCT of reading per DEG C outside 22 - 24 DEG C (current), 0.1 PCT of reading per DEG C outside 22 - 24 DEG C (voltage); Battery life (with typical usage, backlight off): 100 HR; Test leads rated to 1000 V; Weight: 1.8 LB; Jaw size: 58 MM; 3.75 IN Width X 2 IN Depth |
| Reliably handle a wide range of high current applications with 2000 A AC + DC True-RMS, 1400 A AC and 2000 A DC |
| Selectable low-pass filter mode |
| Large display with backlight |
| Inrush current measurement |
| Versatile, professional and accurate |
| IP42 IP, (6) 1.5 V AA NEDA 15 A or IEC LR6 battery, 10/100/1000 mA resolution, -4 to 140 deg F storage temperature, 1 m drop test requirements |
| AC/DC current range 40 A with accuracy of (1.5 % Reading + 15 Digits) at 10 to 100 Hz and 10 mA resolution, 400 A with accuracy of (1.5 % Reading + 5 Digits) at 10 to 100 Hz and 100 mA resolution, 2000 A, 1400 A AC RMS with accuracy of (1.5 % Reading + 5 Digits) at 10 to 100 Hz and 1 A resolution, AC current range 40 A with accuracy of (3.5 % Reading + 15 Digits) at 100.1 to 1 kHz and 10 mA resolution, 400 A with accuracy of (3.5 % Reading + 5 Digits) at 100.1 to 1 kHz and 100 mA resolution, 2000 A, 1400 A AC RMS with accuracy of (3.5 % Reading + 5 Digits) at 100.1 to 1 kHz and 1 A resolution |
| Resistance range 400 Ohm with accuracy of (1.5% + 5 Digit) and 0.1 Ohm resolution, 4 kOhm with accuracy of (1.5% + 5 Digit) and 1 Ohm resolution, 40 kOhm with accuracy of (1.5% + 5 Digit) and 10 Ohm resolution, 400 kOhm with accuracy of (1.5% + 5 Digit) and 100 Ohm resolution |
| AC voltage range 4 V with accuracy of (1% Reading + 10 Digits) at 10 to 100 Hz and 1 mV resolution, 40 V with accuracy of (1% Reading + 5 Digits) at 10 to 100 Hz and 10 mV resolution, 400 V with accuracy of (1% Reading + 5 Digits) at 10 to 100 Hz and 100 mV resolution, 600 VAC RMS with accuracy of (1% Reading + 5 Digits) at 10 to 100 Hz and 10 mV resolution, 4 V with accuracy of (3% Reading + 10 Digits) at 100.1 to 1 kHz and 1 mV resolution, 40 V with accuracy of (3% Reading + 5 Digits) at 100.1 to 1 kHz and 10 mV resolution, 400 V with accuracy of (3% Reading + 5 Digits) at 100.1 to 1 kHz and 100 mV resolution, 600 VAC RMS with accuracy of (3% Reading + 5 Digits) at 100.1 to 1 kHz and 10 mV resolution |
| Continuity beeper ON at <= 30 Ohm, off at >= 100 Ohm |
| The tools of choice for high current clamp-on amp meter measurement up to 2000 A |
| The extra wide jaw easily clamps around large conductors, typically found in high current applications |
| The extra rugged design and Cat IV 600 V, Cat III 1000 V ratings add an extra element of user protection when taking high-powered measurements |
| Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads |
| The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians |
| The large 58 MM jaw capacity is suitable for large or multiple conductors |
| Cat IV 600 VAC, Cat III 1000 VAC rating for added user protection |
| In-rush current measurement captures power-on™ surge current with accuracy and repeatability |
| High voltage measurement of 1000 VAC plus VDC True-RMS, 600 VAC and 1000 VDC allows the user to perform multiple tests with only one tool (355 only |
| Resistance to 400 kOhm coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter (355 only |