Fluke® FLUKE-355 355 Clamp Meter, 600 VAC/1000 VDC, 1400 A AC/2000 A DC, 400 kOhm, 5 Hz to 1 kHz, 2.3 in Jaw, Backlight Display

Clamp Meters
409504 MFG #: FLUKE-355
Fluke®
1139.99000 / ea
Confidently take reliable readings with the true-rms, Fluke 355/353 Clamp Meters; the tools of choice for high-current measurements up to 2000 A. The extra-wide jaw easily clamps around large conductors typically found in highcurrent applications. The rugged design and CAT IV 600 V, CAT III 1000 V ratings, add an extra element of protection when taking high-powered measurements.
QTY
  • Applications
  • Features
For Utilities, Electrical Contractors And Industrial Service Technicians
The tools of choice for high current clamp-on amp meter measurement up to 2000 AMP; The extra-wide jaw easily clamps around large conductors, typically found in high-current applications; The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements; Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads; The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians; Reliably handle a wide range of high-current applications with 2000 AMP AC plus DC true-rms, 1400 AMP AC and 2000 AMP DC; The large 58 MM jaw capacity is suitable for large or multiple conductors; CAT IV 600 V, CAT III 1000 V rating for added user protection; In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability; High voltage measurement of 1000 VAC plus VDC true-rms, 600 VAC and 1000 VDC allows the user to perform multiple tests with only one tool (355 only); Resistance to 400 KOHM coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter (355 only); Accurately measure frequency up to 1 KHZ for optimum troubleshooting; Quickly analyze readings using the minimum, maximum and average functions; A large backlit display allows for easy visibility in low-lit areas; Use the display hold feature to capture readings even when the display cannot be viewed; Use the low-pass filter to smooth out noisy loads and stabilize readings; Jaw capacity: 2-5/16 IN; Battery type: AA; AC response: TRMS; Audible continuity; Auto ranging; Data hold; Inrush and auto power off; Operating humidity: 0 - 95 PCT (non-condensing); Altitude: 2000 MR (operating ) and 10000 MR (Storage ); Drop test requirements 1 M; Temperature coefficients: 0.1 PCT of reading per DEG C outside 22 - 24 DEG C (current), 0.1 PCT of reading per DEG C outside 22 - 24 DEG C (voltage); Battery life (with typical usage, backlight off): 100 HR; Test leads rated to 1000 V; Weight: 1.8 LB; Jaw size: 58 MM; 3.75 IN Width X 2 IN Depth
Reliably handle a wide range of high current applications with 2000 A AC + DC True-RMS, 1400 A AC and 2000 A DC
Selectable low-pass filter mode
Large display with backlight
Inrush current measurement
Versatile, professional and accurate
IP42 IP, (6) 1.5 V AA NEDA 15 A or IEC LR6 battery, 10/100/1000 mA resolution, -4 to 140 deg F storage temperature, 1 m drop test requirements
AC/DC current range 40 A with accuracy of (1.5 % Reading + 15 Digits) at 10 to 100 Hz and 10 mA resolution, 400 A with accuracy of (1.5 % Reading + 5 Digits) at 10 to 100 Hz and 100 mA resolution, 2000 A, 1400 A AC RMS with accuracy of (1.5 % Reading + 5 Digits) at 10 to 100 Hz and 1 A resolution, AC current range 40 A with accuracy of (3.5 % Reading + 15 Digits) at 100.1 to 1 kHz and 10 mA resolution, 400 A with accuracy of (3.5 % Reading + 5 Digits) at 100.1 to 1 kHz and 100 mA resolution, 2000 A, 1400 A AC RMS with accuracy of (3.5 % Reading + 5 Digits) at 100.1 to 1 kHz and 1 A resolution
Resistance range 400 Ohm with accuracy of (1.5% + 5 Digit) and 0.1 Ohm resolution, 4 kOhm with accuracy of (1.5% + 5 Digit) and 1 Ohm resolution, 40 kOhm with accuracy of (1.5% + 5 Digit) and 10 Ohm resolution, 400 kOhm with accuracy of (1.5% + 5 Digit) and 100 Ohm resolution
AC voltage range 4 V with accuracy of (1% Reading + 10 Digits) at 10 to 100 Hz and 1 mV resolution, 40 V with accuracy of (1% Reading + 5 Digits) at 10 to 100 Hz and 10 mV resolution, 400 V with accuracy of (1% Reading + 5 Digits) at 10 to 100 Hz and 100 mV resolution, 600 VAC RMS with accuracy of (1% Reading + 5 Digits) at 10 to 100 Hz and 10 mV resolution, 4 V with accuracy of (3% Reading + 10 Digits) at 100.1 to 1 kHz and 1 mV resolution, 40 V with accuracy of (3% Reading + 5 Digits) at 100.1 to 1 kHz and 10 mV resolution, 400 V with accuracy of (3% Reading + 5 Digits) at 100.1 to 1 kHz and 100 mV resolution, 600 VAC RMS with accuracy of (3% Reading + 5 Digits) at 100.1 to 1 kHz and 10 mV resolution
Continuity beeper ON at <= 30 Ohm, off at >= 100 Ohm
The tools of choice for high current clamp-on amp meter measurement up to 2000 A
The extra wide jaw easily clamps around large conductors, typically found in high current applications
The extra rugged design and Cat IV 600 V, Cat III 1000 V ratings add an extra element of user protection when taking high-powered measurements
Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads
The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians
The large 58 MM jaw capacity is suitable for large or multiple conductors
Cat IV 600 VAC, Cat III 1000 VAC rating for added user protection
In-rush current measurement captures power-on™ surge current with accuracy and repeatability
High voltage measurement of 1000 VAC plus VDC True-RMS, 600 VAC and 1000 VDC allows the user to perform multiple tests with only one tool (355 only
Resistance to 400 kOhm coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter (355 only