CUBEFUSE 15 AMP NON-INP

Cartridge Fuses
541025 MFG #: TCF15RN
Bussmann
72.67000 / ea
  • Alternate Catalog Number: TCF15RN
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: TCF15RN
  • Country of Origin: MUL
  • Currency: USD
  • Element: Dual
  • EU RoHS Indicator: C
  • Gross Weight Per Pack: 0.1000 lb
  • Gross Weight per Pack Metric: 0.46
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536100040
  • Height: 1.89 in
  • Height [Metric]: 4.8006 cm
  • Length: 3.78 in
  • Length [Metric]: 9.6012 cm
  • Material: Glass filled PES
  • Standard: UL Listed ,CSA Certified,RoHS Compliant,CE Marked
  • Standards: ARRA, Buy American Act, CE Marked, CSA Certified, RoHS Compliant, UL Listed
  • Sub Brand: Bussmann Series
  • Type: Fuse
  • UNSPSC: 39121606
  • UPC 11: 05171222092
  • UPC 12: 051712220927
  • Width: 4.57 in
  • Width [Metric]: 11.6002 cm
  • Stock Status: NONSTOCK
  • Brand: Bussmann
  • Manufacturer: Eaton
  • Amperage Rating: 15 A
  • Class: Class CF
  • Connection: Blade end
  • Interrupt Rating: 100 kAIC at 300 Vdc300 kAIC at 600 Vac
  • Mounting: 35 mm Din Rail, chassis
  • Response Time: 10 S at 500%
  • Voltage Rating: 600//300 VAC//VDC
Edison CUBEFuse® Low-Peak Fuse, Time Delay, Series: TCF, Indicating/Non-Indicating: Non-Indicating, Rejection/Non-Rejection: Non-Rejection, 15 A, 600 VAC/300 VDC, 300 kA at 600 VAC/100 kA at 300 VDC Interrupt, Class: CF, 10 s at 500% Response, Plug In Terminal, 35 mm DIN Rail/Chassis Mount, Cartridge Square Body, Dual Element, Glass Filled Polyethersulfone, 1.88 in L x 0.75 in W x 1 in H Body Size
QTY
  • Applications
  • Features
Ind Facilities & Factories - Facility: Safety and Security SystemsDatacenters - Facilities: Power DistributionCommercial / Institutional Buildings / Structures - Critical PowerInd Facilities & Factories - Facility: Power Distribution and ControlStationary Machinery and Equipment Outside Factory - HVAC
Finger safe
Finger safe
The indicating version features easyID™ open fuse technology for faster troubleshooting and reduced downtime
Faster response to damaging faults to help reduce destructive thermal and magnetic forces
True dual element fuse construction with a minimum of 10 s time delay at 500% of rating
Long time delay minimizes nuisance circuit openings due to temporary overloads and transient surges
No venting of arc or molten metal and gases during opening
Robust cycling and inrush current withstand
Low let-through currents under fault conditions
No venting of arc or molten metal and gases during opening
Robust cycling and inrush current withstand
Low let-through currents under fault conditions
Provides type 2 no damage in protection for IEC motors starters when properly sized
Easy selective coordination with any other Cooper Bussmann Low-Peak class CC, L, J and RK1 fuse with simple 2: 1 amp ration between upstream and downstream fuses
-40 to 80 deg C operating temperature
300 kA RMS symmetrical (UL) and 300 kA RMS symmetrical (CSA) at 600 VAC, 100 kA (UL and CSA) at 300 VDC interrupt rating
Copper alloy terminals, Electroless tin terminal plating, energetic chemical indicator
10 sec at 500% response time