O-Z/Gedney EYAX-75 3/4 IN HOR/VERT SEALING
Explosion Proof Conduit Sealing Fittings
499371
MFG #: EYAX75
O-Z/Gedney
30.80000
/ ea
- Application: For Rigid Conduit Or IMC
- ARRA Compliant: N
- Buy American Compliant: N
- Catalog Number: EYAX75
- Connection: Tapered FNPT
- Country of Origin: MX
- Currency: USD
- Dimensions: 1-3/4 in Dia x 4-5/16 in L
- EU RoHS Indicator: N
- Gross Weight Per Pack: 1.8500 lb
- Gross Weight per Pack Metric: 0.84
- Gross Weight UOM Metric: kg
- Height: 0.86 in
- Height [Metric]: 21.8440 mm
- Length: 6.80 in
- Length [Metric]: 17.2720 cm
- Standards: UL File No. E34997CSA 009795 for Wet LocationsClass I Division 1/2 Group A/B/C/D, Class I Zone 1/2 Group IIA, IIB and IIC, Class II Division 1/2 Group E/F/G, Class IIIUL 886CSA C22.2 No. 30NEC 500-503/505Mil-F-28675
- Type: Type EYAX Vertical/Horizontal Sealing Fitting
- UNSPSC: 39121311
- UPC 11: 78312611393
- UPC 12: 783126113938
- Width: 5.20 in
- Width [Metric]: 13.2080 cm
- Stock Status: NONSTOCK
- Brand: O-Z/Gedney
- Manufacturer: O-Z/Gedney
- Finish: Zinc Electroplated
- Material: Malleable Iron
- Size: 3/4 in
- Suitable For Use With: IMC/Rigid Metal Conduit
OZ-Gedney Type EYAX Vertical/Horizontal Sealing Fitting, Size: 3/4 IN, Malleable Iron, Finish: Zinc Electroplated, Connection: Tapered FNPT, Dimensions: 1-3/4 IN Body Diameter X 4-5/16 IN Overall Length, 1-3/8 IN Turning Radius, 2.25 OZ Sealing Co
- Applications
- Features
For Rigid Conduit Or IMC |
To seal vertical or horizontal conduit runs where 40 PCT conductor fill is required; To minimize the passage of gases and vapors and prevent the passage of flames from one portion of the electrical system to another through the conduit; Explosion proof, dust-ignition proof; Use with type EYC sealing compound and type EYF fiber |
To seal vertical or horizontal conduit runs where 40 PCT conductor fill is required |
To minimize the passage of gases and vapors and prevent the passage of flames from one portion of the electrical system to another through the conduit |
Use with type EYC sealing compound and type EYF fiber |
Prevent passage of gases, vapors or flames from one portion of conduit system to another |
Restrict any explosion to the sealed off enclosure |
Prevent pressure piling within conduit system |
Required in class I, division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures |
Required in class I, division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps |
Required in class I, division 1 and 2 locations at the boundary where conduit leaves classified location |
Required in class I, division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure |
Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in class I, division 2 locations |
Smooth, rounded integral bushing in each hub to protect conductor insulation |
Accurately tapped, tapered threads for tight, rigid joints and ground continuity |
Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub |
Allow up to 40% conduit fill in compliance with the national electrical code |