Appleton® EYD6 Unilet® EYD Explosionproof Conduit Sealing Fitting, 2 in, For Use With IMC/Threaded Rigid Metal Conduit
Explosion Proof Conduit Sealing Fittings
254686
MFG #: EYD6
Appleton™
140.23000
/ ea
- Application: For Use With Threaded Rigid Metal Conduit And IMC
- ARRA Compliant: N
- Buy American Compliant: N
- Catalog Number: EYD6
- Color: Gray
- Connection: Tapered FNPT
- Country of Origin: MX
- Currency: USD
- EU RoHS Indicator: C
- Gross Weight Per Pack: 6.3000 lb
- Gross Weight per Pack Metric: 2.15
- Gross Weight UOM Metric: kg
- Height: 3.60 in
- Height [Metric]: 9.1440 cm
- Length: 7.50 in
- Length [Metric]: 19.0500 cm
- Standard: UL 886 (1203), UL File Number E10444, CSA C22.2 No. 30, CSA 065181, UL Listed For Class I, Division 1 And 2 Groups C, D, Class II, Division 1 And 2 Groups E, F, G, Class III
- Standards: UL 886 (1203), File No. E10444, CSA C22.2 No. 30, File No. 065181, Class I, Division 1 and 2, Groups C, D; Class II, Division 1 and 2, Groups E, F, G; Class III NEC/CEC Certified
- Sub Brand: UNILETS
- Type: EYD Series 25 PCT Fill Vertical Conduit Drain Sealing Fitting
- UNSPSC: 39121311
- UPC 11: 78138162081
- UPC 12: 781381620819
- Width: 4.60 in
- Width [Metric]: 11.6840 cm
- Stock Status: NONSTOCK
- Brand: Appleton™
- Manufacturer: Appleton
- Finish: Zinc Electroplate/Chromate/Epoxy Powder Coat
- Material: Grayloy-Iron
- Size: 2 in
These Appleton sealing fittings minimizes the passage of gases and vapors and prevents the passage of flames from one portion of a conduit system to another. They prevent pressure piling the within conduit system and contain any explosion that occurs.
- Applications
- Features
For Use With Threaded Rigid Metal Conduit and IMC |
For preventing passage of gases, vapors or flames from one portion of conduit system to another; Required in Class I, Division 1 and 2 locations within 18 IN of enclosures containing apparatus that may cause arcs, sparks or high temperatures; Required in Class I, Division 1 and 2 locations where 2 IN or larger conduit enters enclosure, fitting housing terminals, splices or taps; Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location; Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 IN or less conduit, seal must be located within 18 IN of either enclosure; Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in Class I, Division 2 locations; Explosionproof, dust-ignitionproof, raintight; Smooth, rounded integral bushing in each hub protects conductor insulation; Accurately tapped, tapered threads for tight, rigid joints and ground continuity; U |
Smooth, rounded integral bushing in each hub protects conductor insulation |
Accurately tapped, tapered threads for tight, rigid joints and ground continuity |
Dust-ignition proof, raintight |
Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub |
Close radius type for sealing vertical conduit runs |
Restrict any explosion to the sealed off enclosure |
Required in class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures |
Required in class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps |
Required in class I, Division 1 and 2 locations at the boundary where conduit leaves classified location |
Required in class I, Division 1 and 2 locations where two or more enclosures are connected by 36 or less conduit, seal must be located within 18 in of either enclosure |
Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in class I, Division 2locations |
2.31 in turning radius |
Tapered FNPT connection |
25% fill vertical conduit drain sealing fittings |
Triple-coat (Zinc electroplate, chromate and epoxy powder coat) finish |
Access cover has drain valve for automatic draining of water accumulation above the sea |