Schneider Electric Meter-Pak™ EZM11600GCBC 3-Wire Meter Center Main Unit With Main Circuit Breaker, 120/240 VAC, 1600 A, 1 Phase, NEMA 3R Enclosure

Meter Sockets - Single Position
PDW~7384953 MFG #: EZM11600GCBC
Square D™
29904.00000 / ea
  • Alternate Catalog Number: EZM11600GCBC
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Cable Entry: UG-OH
  • Catalog Number: EZM11600GCBC
  • Country of Origin: US
  • Currency: USD
  • Enclosure: NEMA 3R,STEEL
  • EU RoHS Indicator: Y
  • Gross Volume Per Pack: 38842.03
  • Gross Volume per Pack Metric: 636508.26
  • Gross Volume UOM: CI
  • Gross Volume UOM Metric: cm3
  • Gross Weight Per Pack: 303.3620 lb
  • Gross Weight per Pack Metric: 137.89
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8537109150
  • Height: 69.22 in
  • Height [Metric]: 177.5000 cm
  • Item Group: 00020
  • Length: 18.21 in
  • Length [Metric]: 46.7000 cm
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=61554212&lang=en-us
  • Mounting: Surface
  • Returnable: Y
  • Size: 30.19 IN,68.7 IN
  • Standard: UL listed
  • Sub Brand: EZ METER-PAK
  • Type: Meter center main unit
  • UNSPSC: 39121102
  • UPC 11: 78590165144
  • UPC 12: 785901651444
  • Warranty Description: Contractual Warranty:18 months
  • Width: 29.91 in
  • Width [Metric]: 76.7000 cm
  • Brand: Square D™
  • Manufacturer: Schneider Electric
  • Amperage Rating: 1200 A,1600 A
  • Phase: 1 PHASE IN-1 PHASE OUT
  • Voltage Rating: 120/240 VAC
Schneider Electric Meter-Pak™ Meter Center Main Unit, 3-Wire, Series: EZM, 120/240 VAC, 1600 A, 1 ph, Overhead/Underground Feed, 6 AWG to 300 kcmil, 1 AWG to 250 kcmil, 1 AWG to 600 kcmil Al/Cu Wire, Closing Plate Hub, Lug Terminal, Surface Mounting, NEMA 3R Enclosure, 68.7 in H x 30.19 in W x 18.33 in D Dimensions
QTY
  • Features
MAIN CIRCUIT BREAKER,ALUMINIUM/COPPER BUSBAR
Top and bottom wiring gutters with knockouts allow branch circuits to exit from either the top, bottom or back of the unit
To suit individual applications, residential and commercial devices may be interconnected
Basic devices for connection to 3 phase 4-wire 120/208 VAC service are factory phase balanced to save installation time
The phase balancing may be modified in the field to meet most system variations
Aluminum horizontal cross busbar upto 1000 A maximum
6 AWG to 300 kcmil ground cable 1, 1 AWG to 250 kcmil line/neutral cable 2, 1 AWG to 600 kcmil line/neutral cable (1) lug