Schneider Electric GV2LE04, 0.63 A, 3 poles

Std Thermal Magnetic Circuit Breakers
PDW~13596218 MFG #: GV2LE04
Square D™
290.00000 / ea
  • Alternate Catalog Number: GV2LE04
  • Application: For 3-phase motor applications 0, For 100 000 cycles AC-3
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: GV2LE04
  • Country of Origin: FR
  • Currency: USD
  • EU RoHS Indicator: Y
  • Gross Volume Per Pack: 61.02
  • Gross Volume per Pack Metric: 1000.00
  • Gross Volume UOM: CI
  • Gross Volume UOM Metric: cm3
  • Gross Weight Per Pack: 0.4930 lb
  • Gross Weight per Pack Metric: 224.00
  • Gross Weight UOM Metric: g
  • Harmonization Tariff Schedule Code: 8536200040
  • Height: 3.32 in
  • Height [Metric]: 8.5000 cm
  • Length: 1.87 in
  • Length [Metric]: 4.8000 cm
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=607210&lang=en-us
  • Returnable: N
  • Size: 3.09 in
  • Sub Brand: TeSys GV2
  • Substitute Product Catalog Number: GVAD1010
  • Type: Motor circuit breaker;GV2LE
  • UNSPSC: 39121521
  • Warranty Description: Contractual Warranty:18 months
  • Width: 3.63 in
  • Width [Metric]: 9.3000 cm
  • Brand: Square D™
  • Manufacturer: Schneider Electric
  • Number Of Poles: 3
Schneider Electric GV2LE04, 0.63 A, 50/60 Hz Frequency, 3 Pole, Screw Connector Connection, IP20 Enclosure, -4 to 140 deg F, 3.50 in H x 1.77 in W x 3.09 in D Dimensions
QTY
  • Applications
  • Features
For 3-phase motor applications 0, For 100 000 cycles AC-3
The GV2 manual starter and protector provides manual isolation, manual motor control, and thermal overcurrent protection in one compact unit
The basic motor starter GV2ME controls motors with full load currents up to 32A
The GV2P, high performance manual starter, offers a higher withstand rating and visible trip indication for convenience
The GV2P has an additional UL 508 type E rating as a stand alone self-protected manual combination starter
Single phase sensitivity
Magnetic instantaneous short-circuit protection
Test trip mechanism
The addition of an undervoltage trip enables the motor circuit-breaker to be tripped if voltage is lost
The addition of a shunt trip enables remote control of tripping
Fingersafe terminals (meets IP20 standards)
Fingersafe terminals (meets IP20 standards)
AC network type
100 % 690 V AC 50/60 Hz IEC 60947-2100 % 500 V AC 50/60 Hz IEC 60947-2100 % 230/240 V AC 50/60 Hz IEC 60947-2100 % 440 V AC 50/60 Hz IEC 60947-2100 % 400/415 V AC 50/60 Hz IEC 60947-2 ics rated service short-circuit breaking capacity
8 A magnetic tripping current
35 mm symmetrical DIN rail: clippedPanel: screwed (with adaptor plate) fixing mode
Any position operating position
690 V AC 50/60 Hz IEC 60947-2 ui rated insulation voltage
6 kV IEC 60947-2 uimp rated impulse withstand voltage
100000 cycles mechanical durability