Siemens 3RV2 Motor Protection Circuit Breaker, 690 VAC, 80 to 100 A, 3 kA Interrupt, 3 Poles, Magnetic Trip
Motor Protection Circuit Breakers
967347
MFG #: 3RV20414MA10
Siemens
795.10000
/ ea
- Alternate Catalog Number: 3RV2041-4MA10
- ARRA Compliant: C
- Buy American Compliant: C
- Catalog Number: 3RV20414MA10
- Connection Type: Screw
- Country of Origin: DE
- Currency: USD
- Dimensions: 165 mm H x 70 mm W x 176 mm D
- Enclosure Type: IP20
- EU RoHS Indicator: C
- Frame: S3
- Frequency Rating: 50 to 60 Hz
- Gross Volume Per Pack: 2810.61
- Gross Volume UOM: in
- Gross Weight Per Pack: 5.0300 lb
- Gross Weight per Pack Metric: 2.28
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8536304000
- Height: 8.0000 in
- Height [Metric]: 20.3200 cm
- Length: 8.1000 in
- Length [Metric]: 20.5740 cm
- Mounting Type: DIN Rail
- Phase: 3 pH
- Power Rating: 90 kW
- Returnable: Y
- Series: 3RV2
- Standards: CSA CertifiedCE CertifiedIEC CertifiedUL Listed
- Temperature Rating: -20 to 60 °C
- Trip Range: 1300 A
- UNSPSC: 39121521
- UPC 11: 80476636495
- UPC 12: 804766364952
- Width: 2.8000 in
- Width [Metric]: 7.1120 cm
- Stock Status: NORMALLY STOCKED
- Brand: Siemens
- Manufacturer: Siemens
- Amperage Rating: 80 to 100 A
- Interrupt Rating: 3 kA
- Trip Type: Magnetic
- Voltage Rating: 690 VAC
- Number Of Poles: 3
The SIRIUS 3RV2 motor starter protectors/circuit breakers are compact, current limiting motor starter protectors/circuit breakers which are optimized for load feeders. The motor starter protectors/circuit breakers are used for switching and protecting three-phase motors of up to 55/45 kW at 400 VAC and for other loads with rated currents of up to 100 A.
- 3D Rendering URL - G_IC03_XX_18993V.pdf(3D Rendering URL)
- http://www.sea.siemens.com(Seller Home Page URL)
- Spec Sheet URL - 10991_KIX095THLQUO68SC.pdf(Spec Sheet URL)
- User Manual URL - man(User Manual URL)
- Spec Sheet URL - DatasheetService?format=PDF&caller=EGH&mlfbs=3RV2041-4MA10&language=en(Spec Sheet URL)
- Spec Sheet URL - DatasheetService?format=PDF&caller=PDPS&mlfbs=3RV2041-4MA10&language=en(Spec Sheet URL)
- Features
Class 10 trip |
Reduction of inherent power loss |
Less heating of the control cabinet |
Smaller control cabinet air conditioners can be used |
3RV2 motor starter protectors/circuit breakers are suitable for operation in IT systems (IT networks) |
30 000 W at 230 VAC, 45 000 W at 400 VAC, 90 000 W at 690 VAC |
100 kA at 240 VAC, 65 kA at 400 VAC, 8 kA at 500 VAC, 5 kA at 690 VAC |
80 to 100 A thermal overload release, 1300 A instantaneous overcurrent release |
Without auxiliary switch |