Siemens 3RV2 Motor Protection Circuit Breaker, 690 VAC, 80 to 100 A, 3 kA Interrupt, 3 Poles, Magnetic Trip
Custom_Product_Images_Illustration
Siemens 3RV2 Motor Protection Circuit Breaker, 690 VAC, 80 to 100 A, 3 kA Interrupt, 3 Poles, Magnetic Trip
SKU967347
MFGR #3RV20414MA10
Your Cost: $851.40/ea
List: The SIRIUS 3RV2 motor starter protectors/circuit breakers are compact, current limiting motor starter protectors/circuit breakers which are optimized for load feeders. The motor starter protectors/circuit breakers are used for switching and protecting three-phase motors of up to 55/45 kW at 400 VAC and for other loads with rated currents of up to 100 A.
The SIRIUS 3RV2 motor starter protectors/circuit breakers are compact, current limiting motor starter protectors/circuit breakers which are optimized for load feeders. The motor starter protectors/circuit breakers are used for switching and protecting three-phase motors of up to 55/45 kW at 400 VAC and for other loads with rated currents of up to 100 A.
Alternate Catalog Number 3RV2041-4MA10 ARRA Compliant C Buy American Compliant C Catalog Number 3RV20414MA10 Connection Type Screw Country of Origin DE Currency USD Dimensions 165 mm H x 70 mm W x 176 mm D Enclosure Type IP20 EU RoHS Indicator C Frame S3 Frequency Rating 50 to 60 Hz Gross Volume Per Pack 2810.61 Gross Volume UOM in Gross Weight Per Pack 5.0300 lb Gross Weight per Pack Metric 2.28 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8536304000 Height 8.0000 in Height [Metric] 20.3200 cm Length 8.1000 in Length [Metric] 20.5740 cm Mounting Type DIN Rail Number Of Poles 3 Phase 3 pH Power Rating 90 kW Returnable Y Series 3RV2 Standards CSA CertifiedCE CertifiedIEC CertifiedUL Listed Temperature Rating -20 to 60 °C Trip Range 1300 A UNSPSC 39121521 UPC 11 80476636495 UPC 12 804766364952 Width 2.8000 in Width [Metric] 7.1120 cm Stock Status NORMALLY STOCKED Brand Siemens Manufacturer Siemens Amperage Rating 80 to 100 A Interrupt Rating 3 kA Trip Type Magnetic Voltage Rating 690 VAC Class 10 trip Reduction of inherent power loss Less heating of the control cabinet Smaller control cabinet air conditioners can be used 3RV2 motor starter protectors/circuit breakers are suitable for operation in IT systems (IT networks) 30 000 W at 230 VAC, 45 000 W at 400 VAC, 90 000 W at 690 VAC 100 kA at 240 VAC, 65 kA at 400 VAC, 8 kA at 500 VAC, 5 kA at 690 VAC 80 to 100 A thermal overload release, 1300 A instantaneous overcurrent release Without auxiliary switch
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
| Alternate Catalog Number | 3RV2041-4MA10 |
| ARRA Compliant | C |
| Buy American Compliant | C |
| Catalog Number | 3RV20414MA10 |
| Connection Type | Screw |
| Country of Origin | DE |
| Currency | USD |
| Dimensions | 165 mm H x 70 mm W x 176 mm D |
| Enclosure Type | IP20 |
| EU RoHS Indicator | C |
| Frame | S3 |
| Frequency Rating | 50 to 60 Hz |
| Gross Volume Per Pack | 2810.61 |
| Gross Volume UOM | in |
| Gross Weight Per Pack | 5.0300 lb |
| Gross Weight per Pack Metric | 2.28 |
| Gross Weight UOM Metric | kg |
| Harmonization Tariff Schedule Code | 8536304000 |
| Height | 8.0000 in |
| Height [Metric] | 20.3200 cm |
| Length | 8.1000 in |
| Length [Metric] | 20.5740 cm |
| Mounting Type | DIN Rail |
| Number Of Poles | 3 |
| Phase | 3 pH |
| Power Rating | 90 kW |
| Returnable | Y |
| Series | 3RV2 |
| Standards | CSA CertifiedCE CertifiedIEC CertifiedUL Listed |
| Temperature Rating | -20 to 60 °C |
| Trip Range | 1300 A |
| UNSPSC | 39121521 |
| UPC 11 | 80476636495 |
| UPC 12 | 804766364952 |
| Width | 2.8000 in |
| Width [Metric] | 7.1120 cm |
| Stock Status | NORMALLY STOCKED |
| Brand | Siemens |
| Manufacturer | Siemens |
| Amperage Rating | 80 to 100 A |
| Interrupt Rating | 3 kA |
| Trip Type | Magnetic |
| Voltage Rating | 690 VAC |
| Class 10 trip |
| Reduction of inherent power loss |
| Less heating of the control cabinet |
| Smaller control cabinet air conditioners can be used |
| 3RV2 motor starter protectors/circuit breakers are suitable for operation in IT systems (IT networks) |
| 30 000 W at 230 VAC, 45 000 W at 400 VAC, 90 000 W at 690 VAC |
| 100 kA at 240 VAC, 65 kA at 400 VAC, 8 kA at 500 VAC, 5 kA at 690 VAC |
| 80 to 100 A thermal overload release, 1300 A instantaneous overcurrent release |
| Without auxiliary switch |