Siemens 3RV2 Motor Protection Circuit Breaker, 690 VAC, 54 to 65 A, 4 kA Interrupt, 3 Poles, Magnetic Trip
Motor Protection Circuit Breakers
1005628
MFG #: 3RV20314JA10
Siemens
365.71000
/ ea
- Alternate Catalog Number: 3RV2031-4JA10
- ARRA Compliant: C
- Buy American Compliant: C
- Catalog Number: 3RV20314JA10
- Connection Type: Screw
- Country of Origin: DE
- Currency: USD
- Dimensions: 140 mm H x 55 mm W x 149 mm D
- Enclosure Type: IP20
- EU RoHS Indicator: C
- Frame: S2
- Frequency Rating: 50 to 60 Hz
- Gross Volume Per Pack: 226.14
- Gross Volume UOM: in
- Gross Weight Per Pack: 2.6000 lb
- Gross Weight per Pack Metric: 1.18
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8536304000
- Height: 7.1000 in
- Height [Metric]: 18.0340 cm
- Length: 7.0000 in
- Length [Metric]: 17.7800 cm
- Mounting Type: DIN Rail
- Phase: 3 pH
- Power Rating: 30 kW
- Returnable: Y
- Series: 3RV2
- Standards: CSA CertifiedCE CertifiedIEC CertifiedUL Listed
- Temperature Rating: -20 to 60 °C
- Trip Range: 845 A
- UNSPSC: 39121601
- UPC 11: 80476606163
- UPC 12: 804766061639
- Width: 2.9000 in
- Width [Metric]: 7.3660 cm
- Wire Size: 18 to 2 AWG
- Stock Status: NORMALLY STOCKED
- Brand: Siemens
- Manufacturer: Siemens
- Amperage Rating: 54 to 65 A
- Interrupt Rating: 4 kA
- Trip Type: Magnetic
- Voltage Rating: 690 VAC
- Number Of Poles: 3
The SIRIUS 3RV2 motor starter protectors/circuit breakers are compact, current limiting motor starter protectors/circuit breakers which are optimized for load feeders. The motor starter protectors/circuit breakers are used for switching and protecting three-phase motors of up to 55/45 kW at 400 VAC and for other loads with rated currents of up to 100 A.
- 3D Rendering URL - G_IC03_XX_08882V.pdf(3D Rendering URL)
- http://www.sea.siemens.com(Seller Home Page URL)
- Video - https://www.youtube.com/embed/5Oq25B99HBo(Video)
- User Manual URL - man(User Manual URL)
- Spec Sheet URL - DatasheetService?format=PDF&caller=EGH&mlfbs=3RV2031-4JA10&language=en(Spec Sheet URL)
- Features
Class 10 trip |
Reduction of inherent power loss |
Less heating of the control cabinet |
Smaller control cabinet air conditioners can be used |
3RV2 motor starter protectors/circuit breakers are suitable for operation in IT systems (IT networks) |
18500 W at 230 VAC, 30000 W at 400 VAC, 45000 W at 500 VAC, 55000 W at 690 VAC |
65 kA at 240 VAC, 65 kA at 400 VAC, 8 kA at 500 VAC, 4 kA at 690 VAC |
54 to 65 A thermal overload release, 845 A instantaneous overcurrent release |
Without auxiliary switch |