Siemens 3RV2 Motor Protection Circuit Breaker, 690 VAC, 54 to 65 A, 4 kA Interrupt, 3 Poles, Magnetic Trip
Custom_Product_Images_Illustration
Siemens 3RV2 Motor Protection Circuit Breaker, 690 VAC, 54 to 65 A, 4 kA Interrupt, 3 Poles, Magnetic Trip
SKU1005628
MFGR #3RV20314JA10
Your Cost: $391.31/ea
List: The SIRIUS 3RV2 motor starter protectors/circuit breakers are compact, current limiting motor starter protectors/circuit breakers which are optimized for load feeders. The motor starter protectors/circuit breakers are used for switching and protecting three-phase motors of up to 55/45 kW at 400 VAC and for other loads with rated currents of up to 100 A.
The SIRIUS 3RV2 motor starter protectors/circuit breakers are compact, current limiting motor starter protectors/circuit breakers which are optimized for load feeders. The motor starter protectors/circuit breakers are used for switching and protecting three-phase motors of up to 55/45 kW at 400 VAC and for other loads with rated currents of up to 100 A.
Alternate Catalog Number 3RV2031-4JA10 ARRA Compliant C Buy American Compliant C Catalog Number 3RV20314JA10 Connection Type Screw Country of Origin DE Currency USD Dimensions 140 mm H x 55 mm W x 149 mm D Enclosure Type IP20 EU RoHS Indicator C Frame S2 Frequency Rating 50 to 60 Hz Gross Volume Per Pack 226.14 Gross Volume UOM in Gross Weight Per Pack 2.6000 lb Gross Weight per Pack Metric 1.18 Gross Weight UOM Metric kg Harmonization Tariff Schedule Code 8536304000 Height 7.1000 in Height [Metric] 18.0340 cm Length 7.0000 in Length [Metric] 17.7800 cm Mounting Type DIN Rail Number Of Poles 3 Phase 3 pH Power Rating 30 kW Returnable Y Series 3RV2 Standards CSA CertifiedCE CertifiedIEC CertifiedUL Listed Temperature Rating -20 to 60 °C Trip Range 845 A UNSPSC 39121601 UPC 11 80476606163 UPC 12 804766061639 Width 2.9000 in Width [Metric] 7.3660 cm Wire Size 18 to 2 AWG Stock Status NORMALLY STOCKED Brand Siemens Manufacturer Siemens Amperage Rating 54 to 65 A Interrupt Rating 4 kA Trip Type Magnetic Voltage Rating 690 VAC Class 10 trip Reduction of inherent power loss Less heating of the control cabinet Smaller control cabinet air conditioners can be used 3RV2 motor starter protectors/circuit breakers are suitable for operation in IT systems (IT networks) 18500 W at 230 VAC, 30000 W at 400 VAC, 45000 W at 500 VAC, 55000 W at 690 VAC 65 kA at 240 VAC, 65 kA at 400 VAC, 8 kA at 500 VAC, 4 kA at 690 VAC 54 to 65 A thermal overload release, 845 A instantaneous overcurrent release Without auxiliary switch
content loaded
content loaded
content loaded
content loaded
- Attributes
- Documents & Resources
- Features
- Substitute Products
| Alternate Catalog Number | 3RV2031-4JA10 |
| ARRA Compliant | C |
| Buy American Compliant | C |
| Catalog Number | 3RV20314JA10 |
| Connection Type | Screw |
| Country of Origin | DE |
| Currency | USD |
| Dimensions | 140 mm H x 55 mm W x 149 mm D |
| Enclosure Type | IP20 |
| EU RoHS Indicator | C |
| Frame | S2 |
| Frequency Rating | 50 to 60 Hz |
| Gross Volume Per Pack | 226.14 |
| Gross Volume UOM | in |
| Gross Weight Per Pack | 2.6000 lb |
| Gross Weight per Pack Metric | 1.18 |
| Gross Weight UOM Metric | kg |
| Harmonization Tariff Schedule Code | 8536304000 |
| Height | 7.1000 in |
| Height [Metric] | 18.0340 cm |
| Length | 7.0000 in |
| Length [Metric] | 17.7800 cm |
| Mounting Type | DIN Rail |
| Number Of Poles | 3 |
| Phase | 3 pH |
| Power Rating | 30 kW |
| Returnable | Y |
| Series | 3RV2 |
| Standards | CSA CertifiedCE CertifiedIEC CertifiedUL Listed |
| Temperature Rating | -20 to 60 °C |
| Trip Range | 845 A |
| UNSPSC | 39121601 |
| UPC 11 | 80476606163 |
| UPC 12 | 804766061639 |
| Width | 2.9000 in |
| Width [Metric] | 7.3660 cm |
| Wire Size | 18 to 2 AWG |
| Stock Status | NORMALLY STOCKED |
| Brand | Siemens |
| Manufacturer | Siemens |
| Amperage Rating | 54 to 65 A |
| Interrupt Rating | 4 kA |
| Trip Type | Magnetic |
| Voltage Rating | 690 VAC |
| Class 10 trip |
| Reduction of inherent power loss |
| Less heating of the control cabinet |
| Smaller control cabinet air conditioners can be used |
| 3RV2 motor starter protectors/circuit breakers are suitable for operation in IT systems (IT networks) |
| 18500 W at 230 VAC, 30000 W at 400 VAC, 45000 W at 500 VAC, 55000 W at 690 VAC |
| 65 kA at 240 VAC, 65 kA at 400 VAC, 8 kA at 500 VAC, 4 kA at 690 VAC |
| 54 to 65 A thermal overload release, 845 A instantaneous overcurrent release |
| Without auxiliary switch |