Siemens 3RV2 Motor Protection Circuit Breaker With 1NO-1NC Transverse Auxiliary Switch, 690 VAC, 0.14 to 0.2 A, 3 Poles
Motor Protection Circuit Breakers
910115
MFG #: 3RV20110BA15
Siemens
140.44000
/ ea
- Alternate Catalog Number: 3RV2011-0BA15
- ARRA Compliant: C
- Auxiliary Contact Rating: 1NO-1NC
- Buy American Compliant: C
- Catalog Number: 3RV20110BA15
- Connection Type: Screw
- Country of Origin: DE
- Currency: USD
- Dimensions: 97 mm H x 45 mm W x 96 mm D
- Enclosure Type: IP20
- EU RoHS Indicator: C
- Frame: S00
- Frequency Rating: 50 to 60 Hz
- Gross Volume Per Pack: 31.19
- Gross Volume UOM: in
- Gross Weight Per Pack: 0.6200 lb
- Gross Weight per Pack Metric: 0.28
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8536304000
- Height: 4.0200 in
- Height [Metric]: 10.2108 cm
- Length: 4.0200 in
- Length [Metric]: 10.2108 cm
- Mounting Type: DIN Rail
- Phase: 3
- Power Rating: 90 W
- Replaced Catalog Number: 3RV10210BA15
- Returnable: Y
- Series: 3RV2
- Standards: CSA CertifiedCE CertifiedIEC CertifiedUL Listed
- Temperature Rating: -20 to 60 °C
- Trip Range: 0.14 to 0.2/2.6
- UNSPSC: 39121601
- UPC 11: 66264392134
- UPC 12: 662643921342
- Width: 1.9300 in
- Width [Metric]: 4.9022 cm
- Wire Size: 18 to 14 AWG
- Stock Status: NONSTOCK
- Brand: Siemens
- Manufacturer: Siemens
- Amperage Rating: 0.14 to 0.2 A
- Interrupt Rating: 100 kA
- Trip Type: Magnetic
- Voltage Rating: 690 VAC
- Number Of Poles: 3
Siemens 3RV20110BA15 MSP S00 0.14-0.2A AUX 1NO 1NC SCREW
- 3D Rendering URL - G_NSA0_XX_93052V.pdf(3D Rendering URL)
- http://www.sea.siemens.com(Seller Home Page URL)
- Spec Sheet URL - DatasheetService?format=PDF&caller=EGH&mlfbs=3RV20110BA15&language=en(Spec Sheet URL)
- Spec Sheet URL - 10991_CN8FPQRSLVWZ3G45.pdf(Spec Sheet URL)
- Spec Sheet URL - DatasheetService?format=PDF&caller=EGH&mlfbs=3RV2011-0BA15&language=en(Spec Sheet URL)
- Spec Sheet URL - DatasheetService?format=PDF&caller=PDPS&mlfbs=3RV2011-0BA15&language=en(Spec Sheet URL)
- User Manual URL - man(User Manual URL)
- Features
Class 10 trip |
Reduction of inherent power loss |
Less heating of the control cabinet |
Smaller control cabinet air conditioners can be used |
3RV2 motor starter protectors/circuit breakers are suitable for operation in IT systems (IT networks) |
30 W at 230 VAC, 60 W at 400 VAC, 60 W at 500 VAC, 90 W at 690 VAC |
100 kA at 240 VAC, 100 kA at 400 VAC, 100 kA at 500 VAC, 100 kA at 690 VAC |
0.14 to 0.2 A thermal overload release, 2.6 A instantaneous overcurrent release |