Schneider Electric PowerPact™ JDL36250U33X Molded Case Circuit Breaker, 600 VAC, 250 A, 3 Poles, Electronic Trip

Molded Case Circuit Breakers
1085492 MFG #: JDL36250U33X
Square D™
2052.91000 / ea
  • Actuator Type: Toggle
  • Alternate Catalog Number: JDL36250U33X
  • Application: Distribution
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: JDL36250U33X
  • Connection: AWG 3/0...350 KCMIL ALUMINIUM/COPPER,LUGS LOAD-LUGS LINE
  • Connection Type: Line/Load Lug
  • Country of Origin: US
  • Currency: USD
  • Dimensions: 6.4 in H x 4.12 in W x 4.36 in D
  • EU RoHS Indicator: Y
  • Frame: J Frame
  • Frequency Rating: 50/60 Hz
  • Gross Weight Per Pack: 5.2000 lb
  • Gross Weight per Pack Metric: 2.36
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536200020
  • Height: 13.0180 in
  • Height [Metric]: 13.0180 cm
  • Item Group: 01107
  • Length: 21.4330 in
  • Length [Metric]: 21.4330 cm
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=92980418&lang=en-us
  • Mounting Type: Surface
  • Operating Temperature: 50 °C
  • Phase: 3 pH
  • Returnable: N
  • Standard: CE-UL LISTED-CSA-IEC-CCC
  • Temperature Rating: 104 °F
  • Trip Range: 250 A
  • Type: 80% Rated
  • UNSPSC: 39121601
  • UPC 11: 78590196540
  • UPC 12: 785901965404
  • Warranty Description: Contractual Warranty:18 months
  • Width: 18.4150 in
  • Width [Metric]: 18.4150 cm
  • Wire Size: 3/0 AWG to 350 kcmil
  • Stock Status: NONSTOCK
  • Brand: Square D™
  • Manufacturer: Schneider Electric
  • Amperage Rating: 250 A
  • Interrupt Rating: 25 kA at 240 VAC/18 kA at 480 VAC/14 kA at 600 VAC/20 kA at 250 VDC
  • Trip Type: electronic
  • Voltage Rating: 600 VAC
  • Number Of Poles: 3
The PowerPact™ H, J and L-frame circuit breakers are designed to protect electrical systems from damage caused by overloads and short circuits. H and J-frame circuit breakers are available with either thermal-magnetic or Micrologic™ electronic trip units. L-frame circuit breakers are available with Micrologic™ electronic trip units only. H and J-frame circuit breakers with thermal-magnetic trip units contain individual thermal (overload) and instantaneous (short circuit) sensing elements in each pole. The amperage ratings of the thermal trip elements are calibrated at 104 deg F free air ambient temperature. Per the National Electric Code® (NEC®) and the Canadian Electrical Code®, standard circuit breakers may only be applied continuously at up to 80% of their rating. Circuit breakers rated for 100% operation are available but require specially-designed enclosures and 194 deg F rated wire.
QTY
  • Applications
  • Features
Distribution
UNIT MOUNT
Rated current from 70 to 250 A
Breaking capacity from 18 to 65 kA at 480 VAC
Common accessories and auxiliaries with other PowerPact™ frames
25 kA at 240 VAC, 18 kA at 480 VAC, 14 kA at 600 VAC interrupt rating