Siemens 3RX9501-2BA00 ASI PS,120/230VAC

PLC Power Supply Modules
626859 MFG #: 3RX95012BA00
Siemens
624.00000 / ea
  • Alternate Catalog Number: 3RX9501-2BA00
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: 3RX95012BA00
  • Country of Origin: RO
  • Currency: USD
  • Dimensions: 125 mm H x 50 mm W x 125 mm D
  • EU RoHS Indicator: C
  • Gross Volume Per Pack: 72.20
  • Gross Volume UOM: in
  • Gross Weight Per Pack: 1.2000 lb
  • Gross Weight per Pack Metric: 0.54
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8504409540
  • Height: 2.37 in
  • Height [Metric]: 6.0198 cm
  • Length: 5.60 in
  • Length [Metric]: 14.2240 cm
  • Powering Capacity: 100 W
  • Returnable: Y
  • Specifications: 84% Efficiency, IP20, Snap-On/DIN Rail Mount
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantCSA CertifiedUL ListedEAC CertifiedRCM CertifiedCE CertifiedABS CertifiedLloyd's RegisterPRS CertifiedRINA CertifiedASi CertifiedBUREAU VERITAS CertifiedWEEE (2012/19/EU)
  • Temperature Rating: -10 to 70 °C
  • Type: AS-Interface
  • UNSPSC: 39122221
  • UPC 11: 75455494505
  • UPC 12: 754554945057
  • Width: 5.44 in
  • Width [Metric]: 13.8176 cm
  • Stock Status: NONSTOCK
  • Brand: Siemens
  • Manufacturer: Siemens
  • Input Current: 6 A
  • Input Voltage: 120/230 VAC
  • Output Current: 2.6 A
  • Output Voltage: 30 VDC
ASI PS,120/230VAC 30VDC,2.6A CLASS 2
QTY
  • Features
With integrated ground fault detection and AS-I data decoupling
Integrated data decoupling as the result, AS-interface is able to convey both data and power along a single line
Integrated ground fault detection the power supply units perform the reliable detection and signaling of ground faults according to IEC 60204-1
The AS-interface voltage can be disconnected automatically in the event of a ground fault
Integrated overload detection an output overload is detected and reported over a diagnostics LED
Diagnostics memory any ground faults or overloads on the output side are stored in a diagnostics memory until the device is reset
Remote reset and remote signaling using relay contacts, a ground fault can be signaled and evaluated by a central controller and/or indicator light
Diagnostics LED 3 different LED indicate the status of the AS-interface power supply locally at the power supply unit
Ultra wide input range/2-phase connection the ultra wide input range of 120 to 500 V of the 8 A version means that the supply units can be used in virtually any network worldwide
In addition, this version dispenses with the need for an N conductor as the device can be connected directly between 2 phases of a network
Removable terminal blocks with spring-type connections for easy exchanging of devices, each power supply unit has three removable terminal blocks: for the input side, for the output side and for Signal/RESET connections
With integrated overload detection with AS-interface data decoupling