Siemens MT1000A Class MT Open Style Control Power Transformer, 240/480 VAC Primary, 120 VAC Secondary, 1000 VA, 50/60 Hz

Control Transformers
361407 MFG #: MT1000A
Siemens
318.20000 / ea
  • Alternate Catalog Number: US2:MT1000A
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: MT1000A
  • Connection Type: Screw
  • Country of Origin: MX
  • Currency: USD
  • Dimensions: 14.3 in L x 10.4 in W x 10.9 in H
  • Enclosure Type: Open
  • EU RoHS Indicator: C
  • Gross Volume Per Pack: 198.00
  • Gross Volume UOM: in
  • Gross Weight Per Pack: 27.1000 lb
  • Gross Weight per Pack Metric: 12.29
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8504330040
  • Height: 10.90 in
  • Height [Metric]: 27.6860 cm
  • Length: 14.30 in
  • Length [Metric]: 36.3220 cm
  • Maximum Amperage Rating: 0.29 A
  • Maximum Input Current: 0.29@240VAC A
  • Mounting Type: Panel
  • Returnable: Y
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantcUL ListedUL ListedCSA Certified
  • Temperature Rating: 120 °C
  • Type: Class MT
  • UNSPSC: 39121026
  • UPC 11: 75455402756
  • UPC 12: 754554027562
  • Width: 10.40 in
  • Width [Metric]: 26.4160 cm
  • Stock Status: NORMALLY STOCKED
  • Brand: Siemens
  • Manufacturer: Siemens
  • Frequency Rating: 60 Hz
  • Phase: 1 ph
  • Power Rating: 1000 VA
  • Primary Voltage: 240/480 VAC
  • Secondary Voltage: 110/115/120 VAC
SIEMENS MT1000A CONTROL TRANSF
QTY
  • Features
Epoxy-encapsulated, fuse clips, Integrally molded barriers, jumpers supplied
Epoxy encapsulated (50 to 750 VA), epoxy resin impregnated (1 to 5 kVA)
Completely seals the transformer coils against moisture, dust, dirt and industrial contaminants for maximum protection in hostile and industrial environments
Fuse clips (most models), factory mounted for integral fusing on the secondary side to save panel space, save wiring time and save the cost of buying an add-on fuse block or kit
Integrally molded barriers, between terminals and transformer, protect against electrical creepage, up to 30% greater terminal contact area permits low loss connections, extra deep barriers reduce the chance of shorts from frayed leads or careless wiring
Terminals, molded into the transformer, are difficult to break during wiring, a full quarter-inch of thread on the #10-32 terminal screws prevents stripping and pullout
Jumpers supplied, two jumper links are standard with all transformers which can be wired for dual primary voltages
Laminations are built with silicon steel to minimize core losses and to increase optimum performance and efficiency
Insulation materials are of the highest rating available for the temperature class
240/480, 230/460, 220/440 VAC primary voltage
0.29 A max at 240 VAC