E100+FBPC1+FB2 FACTORY WIRED

Control Transformers
405918 MFG #: E100WA
SolaHD™
127.63000 / ea
  • Application: Industrial
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: E100WA
  • Connection Type: Lead Wire
  • Country of Origin: VN
  • Currency: USD
  • Dimensions: 3.39 in L x 4.36 in W x 4.41 in H
  • Enclosure Type: IP20
  • EU RoHS Indicator: Y
  • Gross Weight Per Pack: 5.1000 lb
  • Gross Weight per Pack Metric: 2.31
  • Gross Weight UOM Metric: kg
  • Height: 5.60 in
  • Height [Metric]: 14.2240 cm
  • KVA Rating: 0.1
  • Length: 8.00 in
  • Length [Metric]: 20.3200 cm
  • Mounting: Heavy Gauge Steel Mounting Plate
  • Mounting Type: Surface
  • Number Of Phases: 1
  • Series: SBE
  • Standard: cULus Listed: E77014, UL 506, CSA C22.2 No. 66, RoHS Compliant
  • Standards: RoHS CompliantcULus File No. E77014UL 506CSA C22.2 No. 66ANSI C89.1
  • Temperature Rating: 131 °F
  • Type: Type 3AG Encapsulated
  • UNSPSC: 39121026
  • UPC 11: 78347200224
  • UPC 12: 783472002245
  • Wattage: 75 W
  • Width: 4.90 in
  • Width [Metric]: 12.4460 cm
  • Stock Status: NONSTOCK
  • Brand: SolaHD™
  • Manufacturer: Emerson
  • Frequency Rating: 50/60 Hz
  • Phase: 1 pH
  • Power Rating: 0.1 kVA
  • Primary Voltage: 240/480 VAC
  • Secondary Voltage: 120 VAC
The SBE Encapsulated industrial control transformers are epoxy encapsulated to seal the transformer windings against moisture, dirt and industrial contaminants. Extra deep, molded terminal barriers reduce the chance of electrical failure as the result of arcing or frayed lead wires. The rugged construction and proven reliability of the SBE design is uniquely suited for all industrial environments.
QTY
  • Applications
  • Features
Industrial
50-1,000 VA, 50/60 Hz, suitable for world wide applications. Interleaved copper windings reduce I2R losses and maximize efficiency. 55 DEG C/131 DEG F rise, 105 DEG C insulation system to minimize heat. Epoxy encapsulated to protect cores and coils against moisture, dirt, and other contaminants. Meets or exceeds NEMA Standard ST 1 and ANSI C89.1 for load inrush capability. Integrally molded, flame retardant (IEC 707/ISO Class 1210) terminal blocks provide greater terminal contact area and improved conductivity. Heavy gauge steel mounting plate. Mounting dimensions are compatible with similar control transformers. Factory installed primary fuse holder class CC and secondary fuse holder (glass or ceramic (Type 3AG, 1/4"x1-1/4" fuse type)
Interleaved copper windings reduce I2R losses and maximize efficiency
Epoxy encapsulated to protect cores and coils against moisture, dirt and other contaminants
Meets or exceeds NEMA standard ST 1 and ANSI C89.1 for load inrush capability
Integrally molded, flame retardant (IEC 707/ISO class 1210) terminal blocks provide greater terminal contact area and improved conductivity
Heavy gauge steel mounting plate
Mounting dimensions are compatible with similar control transformers
131 deg F rise, 105 deg C insulation system to minimize heat
Factory installed primary fuse holder class CC and secondary fuse holder glass or ceramic (type 3AG, 1/4 in x 1-1/4 in fuse type)
Integrally molded, flame retardant (IEC 707/ISO class 1210) terminal blocks provide greater terminal contact area and improved conductivity
220 x 440, 230 x 460, 240 x 480 VAC primary volt
110/115/120 VAC secondary volt