Fluke® 80K-40 High Voltage Current Probe, 40000 VAC

Test Probes
393197 MFG #: 80K-40
Fluke®
342.99000 / ea
  • Alternate Catalog Number: 382846
  • Application: Extend the voltage measuring capability of an AC/DC voltmeter to 40,000 volts peak AC or DC Overvoltage Category I
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: 80K-40
  • Color: Black/Red
  • Country of Origin: US
  • Currency: USD
  • Diameter: 1/2 in
  • Enclosure: Hard plastic
  • EU RoHS Indicator: U
  • Gross Weight Per Pack: 2.1000 lb
  • Gross Weight per Pack Metric: 0.95
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 9030908922
  • Height: 2.76 in
  • Height [Metric]: 7.0104 cm
  • Length [Metric]: 46.9900 cm
  • Material: Plastic/Steel
  • Measuring Range: 40000 V
  • Model: Fluke 80K 40
  • Standards: ARRA CompliantBuy American Act CompliantECCN EAR99PROP65: This product is in compliance with Prop65; it is not known to contain any chemicals associated with this regulation
  • Tip Material: Steel
  • Type: Current Probe
  • UNSPSC: 41111905
  • UPC 11: 09596900112
  • UPC 12: 095969001120
  • Width: 6.50 in
  • Width [Metric]: 16.5100 cm
  • Stock Status: NONSTOCK
  • Brand: Fluke®
  • Manufacturer: Fluke Corporation
  • Amperage Rating: 40 kV dc or, peak ac, 28 kV rms ac
  • Length: 18.50 in
  • Safety Rating: CAT I
  • Voltage Rating: 40 kVDC/peak AC, 28 VRMs
The 80K-40 is a high voltage probe designed to extend the voltage measuring capability of an AC/DC voltmeter to 40,000 volts peak AC or DC Overvoltage Category I.
QTY
  • Applications
  • Features
Extend the voltage measuring capability of an AC/DC voltmeter to 40,000 volts peak AC or DC Overvoltage Category I
High voltage probe designed to extend the voltage measuring capability of an AC/DC voltmeter to 40000 V peak AC or DC overvoltage category I
Can only be used to make measurements on energy limited circuits within equipment
Do not use this probe to measure high voltages on power distribution systems
Probe provides high accuracy when used with a voltmeter having 10 Mohm input impedance
Accuracy 20 kV to 35 kV - +/-1% at 20 deg C to 30 deg C, add 1% at 10 deg C <20 deg C and >30 deg C to 45 deg C, (for total measurement accuracy add accuracy specification of voltmeter being used) 0 kV to <20 kV
1000:1 division ratio
Unusually high input impedance offered by these resistors minimizes circuit loading and thereby, optimizes measurement accuracy
Intended for low energy applications only