Schneider Electric 8536SGO1V06H662 Series Type S Non Reversing, 440 to 480 VAC V Coil, 3 Poles

NEMA Starters
PDW~11631613 MFG #: 8536SGO1V06H662
Square D™
11447.00000 / ea
  • Alternate Catalog Number: 8536SGO1V06H662
  • Application: For common control, For Type S starters, For full voltage starting and stopping of AC squirrel cage motors
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: 8536SGO1V06H662
  • Connection: Screw clamp terminals
  • Country of Origin: MX
  • Currency: USD
  • EU RoHS Indicator: Y
  • Gross Weight Per Pack: 7.7200 lb
  • Gross Weight per Pack Metric: 3.50
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536504000
  • Height: 1.9685 in
  • Item Group: 21194
  • Length: 3.9370 in
  • Returnable: N
  • Size: 8.75 in
  • UNSPSC: 39121521
  • Warranty Description: Contractual Warranty:18 months
  • Width: 1.9685 in
  • Brand: Square D™
  • Manufacturer: Schneider Electric
  • Coil Voltage: 440 V AC 50 Hz;480 V AC 60 Hz
  • Type: Motor starter;No control units
  • Number Of Poles: 3
Schneider Electric 8536SGO1V06H662, Type S Non Reversing, Series: S Series, 600 VAC, 270 A, 50 Hz Frequency, 75 to 100 hp Motor, 440 to 480 VAC Coil, 3 Pole, 3 ph, Screw Clamp Connection, Solid State TeSys T Overload Relay, No Control Units Control, 17.56 in H x 8.56 in W x 8.75 in D Dimensions
QTY
  • Applications
  • Features
For common control, For Type S starters, For full voltage starting and stopping of AC squirrel cage motors
Without pilot light
A normally open holding circuit contact for three wire control is provided as standard
Sizes 00-2 Starters use a Class 9999 SX11 auxiliary contact as the holding circuit contact
Sizes 3-7 starters use a Class 9999 SX6 auxiliary contact as the holding circuit contact
Class 8536 Type S Sizes 00-6 starters are provided with a melting alloy thermal overload relay as standard
Interchangeable thermal units are available in standard trip (Class 20) Sizes 00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3
Single-phase starters use one thermal unit; 3-phase starters use three thermal units
Class 8536 Size 7 starters are provided with solid state MOTOR LOGICTM which features: Selectable trip Class10/20
Ground fault detection and Communication capabilities for future enhancement ; Ambient insensitive and features phase loss, phase unbalance and over-current protection
Solid state Motor LogicTM overload relays are available for Sizes 00 - 7 starters. These ambient insensitive overload relays provide phase loss protection and phase unbalance protection
NEMA Type 1 General Purpose Enclosure
NEMA Type 1 General Purpose Enclosure
NEMA Type 3R Rainproof, Sleet Resistant for Outdoor Use
NEMA Type 4 & 4X Watertight and Dust tight
NEMA Type 4X Watertight, Dust tight, and Corrosion Resistant Glass - Polyester
NEMA Type 7 & 9 Bolted and Spin-Top for Hazardous Locations
NEMA Type 9 Bolted for Hazardous Locations
NEMA Type 12 Dust tight and Drip tight for Industrial Use
AC coils are available for application on 50-60 Hertz
600Vac and 810A continuous current rated maximum
NEMA Sizes 00-4 are supplied with coils that are designed to operate satisfactorily on line voltages of 85% - 110% of rated voltage