Schneider Electric 8536SGO1V06H662 Series Type S Non Reversing, 440 to 480 VAC V Coil, 3 Poles
NEMA Starters
PDW~11631613
MFG #: 8536SGO1V06H662
Square D™
11447.00000
/ ea
- Alternate Catalog Number: 8536SGO1V06H662
- Application: For common control, For Type S starters, For full voltage starting and stopping of AC squirrel cage motors
- ARRA Compliant: N
- Buy American Compliant: N
- Catalog Number: 8536SGO1V06H662
- Connection: Screw clamp terminals
- Country of Origin: MX
- Currency: USD
- EU RoHS Indicator: Y
- Gross Weight Per Pack: 7.7200 lb
- Gross Weight per Pack Metric: 3.50
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8536504000
- Height: 1.9685 in
- Item Group: 21194
- Length: 3.9370 in
- Returnable: N
- Size: 8.75 in
- UNSPSC: 39121521
- Warranty Description: Contractual Warranty:18 months
- Width: 1.9685 in
- Brand: Square D™
- Manufacturer: Schneider Electric
- Coil Voltage: 440 V AC 50 Hz;480 V AC 60 Hz
- Type: Motor starter;No control units
- Number Of Poles: 3
Schneider Electric 8536SGO1V06H662, Type S Non Reversing, Series: S Series, 600 VAC, 270 A, 50 Hz Frequency, 75 to 100 hp Motor, 440 to 480 VAC Coil, 3 Pole, 3 ph, Screw Clamp Connection, Solid State TeSys T Overload Relay, No Control Units Control, 17.56 in H x 8.56 in W x 8.75 in D Dimensions
- Applications
- Features
For common control, For Type S starters, For full voltage starting and stopping of AC squirrel cage motors |
Without pilot light |
A normally open holding circuit contact for three wire control is provided as standard |
Sizes 00-2 Starters use a Class 9999 SX11 auxiliary contact as the holding circuit contact |
Sizes 3-7 starters use a Class 9999 SX6 auxiliary contact as the holding circuit contact |
Class 8536 Type S Sizes 00-6 starters are provided with a melting alloy thermal overload relay as standard |
Interchangeable thermal units are available in standard trip (Class 20) Sizes 00-6, quick trip (Class 10) Sizes 00-4, and slow trip (Class 30) Sizes 00-3 |
Single-phase starters use one thermal unit; 3-phase starters use three thermal units |
Class 8536 Size 7 starters are provided with solid state MOTOR LOGICTM which features: Selectable trip Class10/20 |
Ground fault detection and Communication capabilities for future enhancement ; Ambient insensitive and features phase loss, phase unbalance and over-current protection |
Solid state Motor LogicTM overload relays are available for Sizes 00 - 7 starters. These ambient insensitive overload relays provide phase loss protection and phase unbalance protection |
NEMA Type 1 General Purpose Enclosure |
NEMA Type 1 General Purpose Enclosure |
NEMA Type 3R Rainproof, Sleet Resistant for Outdoor Use |
NEMA Type 4 & 4X Watertight and Dust tight |
NEMA Type 4X Watertight, Dust tight, and Corrosion Resistant Glass - Polyester |
NEMA Type 7 & 9 Bolted and Spin-Top for Hazardous Locations |
NEMA Type 9 Bolted for Hazardous Locations |
NEMA Type 12 Dust tight and Drip tight for Industrial Use |
AC coils are available for application on 50-60 Hertz |
600Vac and 810A continuous current rated maximum |
NEMA Sizes 00-4 are supplied with coils that are designed to operate satisfactorily on line voltages of 85% - 110% of rated voltage |