Schneider Electric TPRST038 TESYS Series, 24 VDC v coil, IP20 enclosure
IEC Starters
PDW~13603035
MFG #: TPRST038
Square D™
0.00000
/ ea
- Alternate Catalog Number: TPRST038
- ARRA Compliant: N
- Buy American Compliant: N
- Catalog Number: TPRST038
- Country of Origin: FR
- Currency: USD
- Current Rating: 160 mA contactor sealed;160 mA contactor closing
- EU RoHS Indicator: Y
- Gross Volume Per Pack: 53.50
- Gross Volume per Pack Metric: 876.70
- Gross Volume UOM: CI
- Gross Volume UOM Metric: cm3
- Gross Weight Per Pack: 7.7000 lb
- Gross Weight per Pack Metric: 770.00
- Gross Weight UOM Metric: g
- Harmonization Tariff Schedule Code: 8536504000
- Height: 5.0000 in
- Height [Metric]: 5.0000 cm
- Length: 13.0000 in
- Length [Metric]: 13.0000 cm
- Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=471609907&lang=en-us
- Returnable: Y
- Size: 4.53 in
- Standard: CCC;EAC;UL;CSA;B10d = 1369863 cycles contactor with nominal load EN/ISO 13849-1;B10d = 20000000 cycles contactor with mechanical load EN/ISO 13849-1;EN/IEC 60947-1;EN/IEC 60947-4-1;UL 60947-4-1;CSA C22.2 No 60947-4-1
- Sub Brand: TeSys island;TeSys;TPRST
- Substitute Product Catalog Number: TPRBCEIP
- UNSPSC: 39121521
- Warranty Description: Contractual Warranty:18 months
- Width: 12.5000 in
- Width [Metric]: 12.5000 cm
- Brand: Square D™
- Manufacturer: Schneider Electric
- Coil Voltage: 24 V DC supplied by the bus coupler
- Type: Motor starter
Schneider Electric TPRST038, TESYS Series, 480 to 690 VAC, 38 to 40 A, 63 Hz Frequency, 9 kW Motor, 24 VDC Coil, Setting: 76-38 , Remotely/Automatically Reset, IP20 Enclosure, 30 cycles Operating Cycles, 14 to 122,122 to 140 deg F Operating, 4.76 in H x 1.77 in W x 4.53 in D Dimensions
- 360 Degree View URL - 360(360 Degree View URL)
- 360 Degree View URL - index.html?pid=11003&id=15646072360Den&ext=webp(360 Degree View URL)
- Brochure URL - 4ad1390261672441990b5f618e66469b7596caf3.pdf(Brochure URL)
- Computer~Aided [CAD|BIM] Model URL(Computer~Aided [CAD|BIM] Model URL)
- Install Instructions 1 URL - 11003_QLC9HZKI17DUV6RO.pdf(Install Instructions 1 URL)
- Seller Home Page URL - us(Seller Home Page URL)
- Service Manual URL - 11003_REQ7A3HKGTVIDFXL.pdf(Service Manual URL)
- Service Manual URL - 11003_Y6UQ5FA1BKI0982N.pdf(Service Manual URL)
- Spec Sheet URL - 11003_EHI8V20KA6BN4XYO.pdf(Spec Sheet URL)
- Tech Bulletin URL - 11003_LE1G2QYD6VBOP9FR.pdf(Tech Bulletin URL)
- Tech Bulletin URL - 11003_ZAH56YQLCKON3UB1.pdf(Tech Bulletin URL)
- User Manual URL - 11003_U5RX01TOCIFKSH98.pdf(User Manual URL)
- User Manual URL - 11003_WLPKBI8XV32MGAJZ.pdf(User Manual URL)
- User Manual URL - files?p_enDocType=User guide&p_File_Name=8536IB1914EN-03.pdf(User Manual URL)
- Features
Direct starter connected to an automation controller through a bus coupler;operational only when connected to a bus coupler;Upstream voltage presence detection;electrical line and load protection;power and energy monitoring when connected with TPRVM voltage module; for DS (device status) 1 LED (green/red); for LS (load status) 1 LED (green/red) |
The system manages motors and other electrical loads up to 40 HP |
Up to 20 modules and 1 bus coupler (up to 112cm length) |
One-click mounting on DIN rail and no need for control wiring on modules |
No auxiliary wiring required, thanks to full connectivity over fieldbus |
Digital & Analog I/Os available |
Different products complaints with international standards (IEC / UL / CSA 61010, IEC / UL / CSA 60947, GB/T14018) |
Only 20 commercial references for the complete system, including 5 standard motor starters and 5 SIL motor starters for functional safety systems as defined in IEC 61508, IEC 62061 and ISO 13849-1 |
Energy monitoring at load level |
Cybersecurity embedded into the system (Achilles Level 2) |
Open connectivity thanks to EtherNet/IP and Modbus TCP fieldbuses |
Open connectivity thanks to EtherNet/IP and Modbus TCP fieldbuses |
Direct starter connected to an automation controller through a bus couplerOperational only when connected to a bus coupler device presentation |
690 V IEC 60947-4-1 600 V UL 60947-4-1 600 V CSA C22.2 No 60947-4-1 ui rated insulation voltage |
6 kV IEC 60947-1 uimp rated impulse withstand voltage |
IIIII overvoltage category |
0.76 to 38 A thermal protection adjustment range |
Class 5 to 30 thermal overload class |
Remotely or automatically reset |
430 A 104 deg F (40 deg C) - 1 s310 A 104 deg F (40 deg C) - 10 s150 A 104 deg F (40 deg C) - 1 min60 A 104 deg F (40 deg C) - 10 min icw rated short-time withstand current |