Telemecanique XCSE73117 XCSE, 220 to 240 V, 3 Poles

Interlock Switches - Trap Key
PDW~13603944 MFG #: XCSE73117
Telemecanique Sensors
490.00000 / ea
  • Action: SLOW-BREAK, BREAK BEFORE MAKE
  • Alternate Catalog Number: XCSE73117
  • Application: For electrical connection and 2 cable entry tapped for PG13 cable gland, For the protection of operators, by controlling the safe opening and interlocking of guards and covers
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: XCSE73117
  • Connection: Terminal 1 x 0.5...2 x 1.5 mm² with or without cable end
  • Contact Configuration: 2 NC + 1 NO
  • Country of Origin: FR
  • Currency: USD
  • EU RoHS Indicator: Y
  • Gross Volume Per Pack: 63.14
  • Gross Volume per Pack Metric: 1034.68
  • Gross Volume UOM: CI
  • Gross Volume UOM Metric: cm3
  • Gross Weight Per Pack: 2.8800 lb
  • Gross Weight per Pack Metric: 1.31
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536509055
  • Height: 4.29 in
  • Height [Metric]: 11.0000 cm
  • Length: 2.11 in
  • Length [Metric]: 5.4000 cm
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=859244&lang=en-us
  • Returnable: N
  • Sub Brand: XCSE
  • Substitute Product Catalog Number: XCSZ90
  • Type: SAFETY SWITCH
  • UNSPSC: 39122213
  • Warranty Description: Contractual Warranty:18 months
  • Width: 5.97 in
  • Width [Metric]: 15.3000 cm
  • Brand: Telemecanique Sensors
  • Manufacturer: Telemecanique Sensors
  • Voltage Rating: 24 V - 20...10 %
  • Number Of Poles: 3
Telemecanique XCSE73117, Series: XCSE, 220 to 240 V, 2NC+1NO Contact Configuration, 3 Pole, Terminal Connection, IP67 Enclosure, -13 to 104 deg F Operating, Metal, Environmental Conditions: -40 to 158 deg F Storage Temperature, -13 to 104 deg F Operating Temperature
QTY
  • Applications
  • Features
For electrical connection and 2 cable entry tapped for PG13 cable gland, For the protection of operators, by controlling the safe opening and interlocking of guards and covers
for guard open/guard closed and locked 2 LEDs (green or orange);Locking on de-energisation and unlocking on energisation of solenoid;Overvoltage protection signalling circuit
Rectangular design
2 entries tapped Pg 13.5 cable entry
Locking on de-energisation and unlocking on energisation of solenoid electromagnet interlocking
24 V - 20 to 10 % us solenoid rated supply voltage
0.35 to 0.47 in 9 to 12 mm cable outer diameter
With interlocking, locking by solenoid locking options description
24/48 V 20 to 52 V signalling circuit voltage
With NC contact positive opening
1 load factor
7 mA signalling circuit consumption
7 mA signalling circuit consumption
1000000 cycles mechanical durability
03 ft/s 01 m/s minimum actuation speed
1.64 ft/s 0.5 m/s maximum actuation speed
50 VEN/IEC 60947-1 signalling circuit ui rated insulation voltage
6 kV EN/IEC 60947-5-1 uimp rated impulse withstand voltage
Overvoltage protection signalling circuit protection type
10 A cartridge fuse gG gl short-circuit protection
2000 N actuator forcible withdrawal rtc
20 N minimum actuator force for extraction