Telemecanique XMLPM00GC7BF XMLP Series Electronic Pressure Sensors, Pressure Sensor sensing, 2 ms response, Analogue output, 24 VDC
Pressure Sensors
PDW~12050246
MFG #: XMLPM00GC7BF
Telemecanique Sensors
256.50000
/ ea
- Alternate Catalog Number: XMLPM00GC7BF
- ARRA Compliant: N
- Buy American Compliant: N
- Catalog Number: XMLPM00GC7BF
- Country of Origin: CH
- Currency: USD
- EU RoHS Indicator: Y
- Gross Volume Per Pack: 61.02
- Gross Volume per Pack Metric: 1000.00
- Gross Volume UOM: CI
- Gross Volume UOM Metric: cm3
- Gross Weight Per Pack: 0.2100 lb
- Gross Weight per Pack Metric: 95.00
- Gross Weight UOM Metric: g
- Harmonization Tariff Schedule Code: 9026204000
- Height: 4.1000 in
- Height [Metric]: 4.1000 cm
- Increasing Range: -14.50…0.00 psi (-1…0 bar)
- Item Group: 21561
- Length: 8.5000 in
- Length [Metric]: 8.5000 cm
- Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=424720606&lang=en-us
- Returnable: N
- Type: Pressure transmitter;Electronic pressure sensors
- UNSPSC: 39122228
- Width: 4.5000 in
- Width [Metric]: 4.5000 cm
- Brand: Telemecanique Sensors
- Manufacturer: Telemecanique Sensors
Telemecanique XMLPM00GC7BF, Electronic Pressure Sensors, XMLP Series, Pressure Sensor Sensing Method, 2 ms Response, Analogue Output, 24 VDC, 7 mA, Male connector Connection, -14.50 to 0.00 psi Pressure, 2.28 in L Size, IP65 Enclosure, -30 to 85 deg C Operating, Environmental Conditions: -58 to 212 deg F Storage Temperature
- Features
Without local display |
0.5 kV uimp rated impulse withstand voltage |
Fresh water 32 to 257 deg F (0 to 125 deg C))Air 5 to 257 deg F (-15 to 125 deg C))Gas 5 to 257 deg F (-15 to 125 deg C))Hydraulic oil 5 to 257 deg F (-15 to 125 deg C)) controlled fluid |
Individual type of packing |
-14.50 to 00 psi (-1 to 0 bar) pressure setting range |
Any position operating position |
Reverse polarity, Load short-circuit protection type |
+/- 0.5 % of the measuring range measurement accuracy |
0.1 % of the measuring range resolution |
+/- 02 % of measuring range/ deg K drift of the zero point |
+/- 02 % of measuring range/ deg K drift of the zero point |
+/- 0.25 % of the measuring range long term stability |
10000000 cycles mechanical durability |
12 in (26 mm) diameter |