Telemecanique XMLB004A2C11 XMLB Series Adjustable Differential, Pressure Sensor sensing

Pressure Sensors
PDW~12913676 MFG #: XMLB004A2C11
Telemecanique Sensors
334.50000 / ea
  • Alternate Catalog Number: XMLB004A2C11
  • Application: For regulation of pressure between 2 thresholds for air, fresh water and hydraulic
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: XMLB004A2C11
  • Contact Configuration: 1 C/O
  • Country of Origin: FR
  • Currency: USD
  • Enclosure: Zinc alloy
  • EU RoHS Indicator: Y
  • Gross Volume Per Pack: 141.26
  • Gross Volume per Pack Metric: 2314.83
  • Gross Volume UOM: CI
  • Gross Volume UOM Metric: cm3
  • Gross Weight Per Pack: 2.3890 lb
  • Gross Weight per Pack Metric: 1.09
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 9032200000
  • Height: 2.81 in
  • Height [Metric]: 7.2000 cm
  • Item Group: 22661
  • Length: 5.26 in
  • Length [Metric]: 13.5000 cm
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=862062&lang=en-us
  • Returnable: N
  • Sub Brand: XMLB
  • Substitute Product Catalog Number: XZCC43FCP40B
  • Type: Electromechanical pressure sensor;Electromechanical pressure sensor;Adjustable differential
  • UNSPSC: 39122210
  • Warranty Description: Contractual Warranty:18 months
  • Width: 4.29 in
  • Width [Metric]: 11.0000 cm
  • Brand: Telemecanique Sensors
  • Manufacturer: Telemecanique Sensors
Telemecanique XMLB004A2C11, Adjustable Differential, XMLB Series, Pressure Sensor Sensing Method, 3 A, Male connector Connection, 58.02 psi Pressure, 6.22 in H x 1.38 in W x 35 in D Size, IP65 Enclosure, -25 to 70 deg C Operating, Environmental Conditions: -40 to 158
QTY
  • Applications
  • Features
For regulation of pressure between 2 thresholds for air, fresh water and hydraulic
With local display
6 kV EN/IEC 60947-1 uimp rated impulse withstand voltage
Air 32 to 158 deg F (0 to 70 deg C))Fresh water 32 to 158 deg F (0 to 70 deg C))Hydraulic oil 32 to 158 deg F (0 to 70 deg C)) controlled fluid
3.63 to 582 psi (0.25 to 4 bar) adjustable range of switching point on rising pressure
0.73 to 54.39 psi (05 to 3.75 bar) adjustable range of switching point on falling pressure
34.81 psi (2.4 bar) possible differential maximum at high setting
Diaphragm pressure actuator
2.90 psi (0.2 bar) +/- 01 bar) possible differential minimum at low setting
3.63 psi (0.25 bar) - 03 bar, + 05 bar) possible differential minimum at high setting
300 V UL 508500 V EN/IEC 60947-1300 V CSA C22.2 No 14 ui rated insulation voltage
300 V UL 508500 V EN/IEC 60947-1300 V CSA C22.2 No 14 ui rated insulation voltage
Silver contacts contacts material
25 mOhm IEC 255-7 category 325 mOhm NF C 93-050 method A maximum resistance across terminals
10 A cartridge fuse gG (gl) short-circuit protection
8000000 cycles mechanical durability
External setting
TC standard version protective treatment
Any position operating position
Class I IEC 1140Class I IEC 536Class I NF C 20-030 electrical shock protection class