Schneider Electric TeSys® LUCA1XBL 3-Phase Standard Starter Control Switch With Class 10 Solid State Reset, 3 Poles

Starter Renewal Parts
244976 MFG #: LUCA1XBL
Schneider Electric
120.00000 / ea
  • Alternate Catalog Number: LUCA1XBL
  • Application: Motor control;motor protection
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: LUCA1XBL
  • Coil Voltage: 24 V DC;20...27 V DC 24 V in operation;14.5 V DC 24 V drop-out
  • Country of Origin: FR
  • Currency: USD
  • EU RoHS Indicator: Y
  • Gross Volume Per Pack: 28.41
  • Gross Volume per Pack Metric: 465.56
  • Gross Volume UOM: CI
  • Gross Volume UOM Metric: cm3
  • Gross Weight Per Pack: 0.2600 lb
  • Gross Weight per Pack Metric: 117.00
  • Gross Weight UOM Metric: g
  • Harmonization Tariff Schedule Code: 8536308000
  • Height: 3.94 in
  • Height [Metric]: 10.1000 cm
  • Item Group: 22397
  • Length: 3.12 in
  • Length [Metric]: 8.0000 cm
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=640668&lang=en-us
  • Mounting: FRONT SIDE,PLUG-IN
  • Power Supply: 24 VDC
  • Reset Type: SOLID STATE (CLASS 10)
  • Returnable: Y
  • Series: LUCA
  • Size: 2.36 in
  • Specifications: 600 VAC, 1.4 A, 0.25 kW, 50/60 Hz, 0.35 to 1.4 A Full Load Current, 24 VDC Coil
  • Sub Brand: TESYS
  • Substitute Product Catalog Number: LUFN02
  • Type: 3-Phase Solid State Standard
  • UNSPSC: 39121521
  • UPC 11: 78590122211
  • UPC 12: 785901222118
  • Voltage Rating: 600 V CONFORMING TO UL 508-690 V CONFORMING TO IEC 60947-1-600 V CONFORMING TO CSA C22.2 NO 14
  • Warranty Description: Contractual Warranty:18 months
  • Width: 2.07 in
  • Width [Metric]: 5.3000 cm
  • Stock Status: NORMALLY STOCKED
  • Brand: Schneider Electric
  • Manufacturer: Schneider Electric
  • Number Of Poles: 3
  • Suitable For Use With: ASILUFC5, ASILUFC51, LUFC00 and LUFN Communication Module
Schneider Electric LUCA1XBL STD.CNTRL.UNIT-CL10-3PH 0.3-1.4A 24VDC,-25...70 deg.C,0.35...1.4 A,24 Vdc,3-Phase,600 V conforming to CSA C22.2 No 14-600 V conforming to UL 508-690 V conforming to IEC 60947-1,IP20 front panel and wired terminals conforming to IEC 60947-1-IP20 other faces conforming to IEC 60947-1-IP40 front panel outside connection zone conforming to IEC 60947-1,LUCA,earth fault protection-protection against overload and short-circuit-manual reset-protection against phase failure and phase imbalance,standard control unit,LUFN..-LUFC00-ASILUFC51-ASILUFC5,basic protection requirements for motor starters overload and short-circuit,Solid State (Class 10),TeSys,TeSys U,front side,plug-in
QTY
  • Applications
  • Features
Motor control;motor protection
PROTECTION AGAINST OVERLOAD AND SHORT-CIRCUIT-PROTECTION AGAINST PHASE FAILURE AND PHASE IMBALANCE-MANUAL RESET-EARTH FAULT PROTECTION
IP20 front panel and wired terminals and IP40 front panel outside connection zone
Front side plug-in mounting location
Earth fault protection, manual reset protection against overload and short circuit protection against phase failure and phase imbalance
Provide basic protection requirements for motor starters
Earth fault protection, manual reset protection against overload and short circuit protection against phase failure and phase imbalance
Provide basic protection requirements for motor starters
14.2 times the FLA setting 0.3 A to 1.4 A
Class 10, frequency limit 40 - 60 Hz, temperature compensation -13 to 158 deg F (-25 to 70 deg C) conforming to UL 508 overload tripping class
Standard - contains solid state overload relay and control power source