Schneider Electric Altivar 212 ATV212HD22N4 Variable Speed Drive With Heat Sink, 480 VAC, 33.1/41.6 A, 30 hp, 9.45 in W

AC Variable Frequency Drives
647571 MFG #: ATV212HD22N4
Schneider Electric
3427.20000 / ea
  • Alternate Catalog Number: ATV212HD22N4
  • Application: Asynchronous motors;Pumps and fans in HVAC;
  • ARRA Compliant: N
  • Brand: Schneider Electric
  • Buy American Compliant: N
  • Catalog Number: ATV212HD22N4
  • Control: +/- 10 OF NOMINAL SLIP 0.2 TN TO TN
  • Country of Origin: CN
  • Currency: USD
  • Display: for DC bus energized 1 LED (red)
  • Display Type: Analog
  • Enclosure: OPEN IP20
  • Enclosure Type: Open/IP20/IP21/IP41
  • EU RoHS Indicator: Y
  • Gross Volume Per Pack: 5409.59
  • Gross Volume per Pack Metric: 88646.95
  • Gross Volume UOM: CI
  • Gross Volume UOM Metric: cm3
  • Gross Weight per Pack Metric: 13.50
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8504404000
  • Horsepower: 30 hp
  • Item Group: 22158
  • Manufacturer: Schneider Electric
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=61737726&lang=en-us
  • Number Of Phases: 3
  • Returnable: Y
  • Standard: IP21
  • Stock Status: NONSTOCK
  • Sub Brand: ATV212
  • Substitute Product Catalog Number: VW3A1101
  • Type: 3-Phase
  • UNSPSC: 39122001
  • UPC 11: 78590192147
  • UPC 12: 785901921479
  • Warranty Description: Contractual Warranty:18 months
Schneider Electric ATV212HD22N4 SPEEDDRIVE 380-480VAC 30HP,ATV212,22kW,3 phases,400/480 Vac 3-Phase,Altivar 212,Altivar 212,Maximum output voltage equal to input voltage 3-Phase,Modbus-METASYS N2-LonWorks-APOGEE FLN-BACnet,Modbus-METASYS N2-LonWorks-APOGEE FLN-BACnet,pumps and fans in HVAC,Open IP20,Size 5A,variable speed drive
QTY
  • Features
VIA, VIB, FM, FLA, FLB, FLC, RY, RC, F, R, RES terminal 2.5-2.5 mm² / AWG 14;L1/R, L2/S, L3/T terminal 50-50 mm² / AWG 1/0;Voltage/frequency ratio, 2 points;voltage/frequency ratio - Energy Saving, quadratic U/f;voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo);flux vector control without sensor, standard;voltage/frequency ratio, 5 points;Overheating protection drive;line supply undervoltage drive;against input phase loss drive;thermal protection motor;motor phase break motor;with PTC probes motor;thermal power stage drive;short-circuit between motor phases drive;input phase breaks drive;overcurrent between output phases and earth drive;overvoltages on the DC bus drive;break on the control circuit drive;against exceeding limit speed drive;line supply overvoltage and undervoltage drive;Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, <10 A overload and short-circuit protection;internal supply 24 V DC 21-27 V), <200 A overload and short-circuit protection
Maximum output voltage equal to input voltage 3-phase output