Schneider Electric TeSys™ LADR0 Time Delay Auxiliary Contact Block, 690 VAC, 0.41 A, 1NO/1NC Contacts

Auxiliary Contacts
97154 MFG #: LADR0
Square D™
157.20000 / ea
  • Alternate Catalog Number: LADR0
  • Application: TeSys D CAD;TeSys D LC1D;TeSys F LC1F;TeSys F CR1F;TeSys Deca CAD;TeSys Deca LC1D
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Catalog Number: LADR0
  • Coil Voltage: 690 V AC 25...400 HZ
  • Contact Configuration: 1 NO + 1 NC
  • Contact Rating: 10 A 60 A°C
  • Country of Origin: FR
  • Currency: USD
  • Environmental Conditions: IP2X, 3000 m Operating Altitude
  • EU RoHS Indicator: Y
  • Frequency Rating: 400 Hz
  • Gross Volume Per Pack: 9.88
  • Gross Volume per Pack Metric: 161.90
  • Gross Volume UOM: CI
  • Gross Volume UOM Metric: cm3
  • Gross Weight Per Pack: 0.1700 lb
  • Gross Weight per Pack Metric: 75.00
  • Gross Weight UOM Metric: g
  • Harmonization Tariff Schedule Code: 8536509065
  • Height: 2.03 in
  • Height [Metric]: 5.2000 cm
  • Item Group: 22341
  • Length: 1.95 in
  • Length [Metric]: 5.0000 cm
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=609920&lang=en-us
  • Maximum Contact Block: 1
  • Mounting: CLIP-ON (FRONT)
  • Mounting Type: Front
  • Operating Cycles: 5000000 Cycles
  • Operating Temperature: -5 to 60 °C
  • Returnable: Y
  • Series: LAD
  • Size: 2.40 in
  • Standard: CSA-UL,IP2X VDE 0660,NF C 63-140-EN 60947-5-1-VDE 0660-BS 4794-IEC 60947-5-1
  • Standards: UL Listed, CSA Certified, BS 4794, EN 60947-5-1, IEC 60947-5-1, NF C 63-140, VDE 0660
  • Sub Brand: TeSys D
  • Suitable For Use With: TeSys D Contactor
  • Type: Time Delay
  • UNSPSC: 39121529
  • UPC 11: 78590121385
  • UPC 12: 785901213857
  • Warranty Description: Contractual Warranty:18 months
  • Width: 2.54 in
  • Width [Metric]: 6.5000 cm
  • Stock Status: NONSTOCK
  • Brand: Square D™
  • Manufacturer: Schneider Electric
  • Amperage Rating: 0.41 A
  • Voltage Rating: 690 VAC
Schneider Electric LADR0 CONTACTOR TIME DELAY AUX.CONTACT BLOCK,1 NO + 1 NC,10 A at <= 60 deg.C,Clip-On (Front),Off-Delay Auxiliary,Screw Clamp,TeSys,TeSys F-TeSys D control relay-TeSys D,UL Listed (E164862 / NLDX) - CSA Certified (LR43364 3211 04) - IEC Rated (60647-4) - CE Marked - RoHS Compliant,time delay auxiliary contact block
QTY
  • Applications
  • Features
TeSys D CAD;TeSys D LC1D;TeSys F LC1F;TeSys F CR1F;TeSys Deca CAD;TeSys Deca LC1D
NORMAL ENVIRONMENT
Screw clamp terminals
600/690 VAC rated insulation voltage
10 A at <= 60 deg C conventional free air thermal current
140 A AC conforming to IEC 60947-5-1, 250 A DC conforming to IEC 60947-5-1
100 A at -5 to 60 deg C 1 sec, 120 A at -5 to 60 deg C 500 m sec, 140 A at -5 to 60 deg C 100 m sec permissible short-time rating
GG fuse <= 10 A rating according to operational current for Ue <= 690 VAC
5 mA minimum switching current
17 V minimum switching voltage
1.5 m sec non-overlap time
Off delay timer type
0.1 to 3 sec time delay range
> 10 M Ohm insulation resistance
IP2X conforming to VDE 0106
TH conforming to IEC 60068
3000 m operating altitude