Bussmann® FRS-R-1/10 FRS-R Current Limiting Time Delay Fuse, 0.1 A, 600 VAC, 200/20 kA Interrupt, Class RK5, Cartridge Body

Class RK5 Fuses
69145 MFG #: FRS-R-1/10
Bussmann
35.32000 / ea
  • Alternate Catalog Number: FRS-R-1/10
  • Application: Ind Facilities & Factories - Facility: Safety and Security Systems
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: FRS-R-1/10
  • Connection: Ferrule end x ferrule end
  • Country of Origin: MUL
  • Currency: USD
  • Element: Dual
  • EU RoHS Indicator: C
  • Gross Weight Per Pack: 0.1500 lb
  • Gross Weight per Pack Metric: 0.07
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536100040
  • Height: 5.00 in
  • Height [Metric]: 12.7000 cm
  • Length: 5.00 in
  • Length [Metric]: 12.7000 cm
  • Response Time: 10 S at 500%
  • Size: 0.81 In Diameter X 5.00 In Length
  • Standard: CE Marked
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantCE CertifiedUL 248-12 File No. E4273 Guide JDDZCSA File No. 53787 C22.2 No. 248.12 Class 1422-02
  • Sub Brand: Bussmann Series
  • Type: Fuse
  • UNSPSC: 39121606
  • UPC 11: 05171250800
  • UPC 12: 051712508001
  • Width: 0.81 in
  • Width [Metric]: 2.0574 cm
  • Stock Status: NONSTOCK
  • Brand: Bussmann
  • Manufacturer: Eaton
  • Amperage Rating: 10m A
  • Class: RK-5
  • Interrupt Rating: 200 kAIC at 600 Vac20 kAIC at 300 Vdc
  • Voltage Rating: 600//300 VAC//VDC
Bussmann Time Delay Fuse, Current Limiting, Series: FRS-R, Indicating/Non-Indicating: Indicating, Rejection/Non-Rejection: Rejection, 0.1 A, 600 VAC, 200/20 kA Interrupt, Class: RK5, 10 sec Response, Ferrule Terminal, Holder Mount, Cartridge Body, Dual Element, Fiberglass, 0.81 in Dia x 5 in L Body Size
QTY
  • Applications
  • Features
Ind Facilities & Factories - Facility: Safety and Security Systems
Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short circuit and overload protection
Offers a 10-second time delay at 5 times the rated current
The time-delay feature makes it possible to use fuse amp ratings that are much smaller than those of non-time delay fuses, considerable cost savings occur by permitting the use of smaller size switches, panels and fuses themselves
Provides current limitation to help protect downstream components from high fault currents
Gives motor running back-up protection to motors without extra costs
Dual-element feature provides the best time-delay performance, allowing closer sizing and superior protection of motors and transformers
Closer sizing allows for smaller fuses and less costly switches
Provides motor overload ground fault, and short circuit protection
Helps protect motors against burnout from overloads and single phasing when sized properly
200 kA Vac RMS Symmetrical, 20 kA Vdc of interrupting rating