Bussmann® LPS-RK-400SP LOW-PEAK DUAL ELE

Class RK1 Fuses
5295 MFG #: LPS-RK-400SP
Bussmann
281.60000 / ea
  • Alternate Catalog Number: LPS-RK-400SP
  • Application: Ind Facilities & Factories - Facility: Safety and Security Systems
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: LPS-RK-400SP
  • Connection: Blade end x blade end
  • Country of Origin: MX
  • Currency: USD
  • Element: Dual
  • EU RoHS Indicator: C
  • Gross Weight Per Pack: 2.3500 lb
  • Gross Weight per Pack Metric: 2.09
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536100040
  • Height: 2.70 in
  • Height [Metric]: 6.8580 cm
  • Length: 12.10 in
  • Length [Metric]: 30.7340 cm
  • Response Time: 10 S at 500%
  • Size: 2.36 In Diameter X 11.63 In Length
  • Standard: RoHS Compliant,CE Marked
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantUL Listed, Guide JDDZ, File No. E4273CSA C22.2 No. 248.12, Class 1422-02, File No. 53787CE Certified
  • Sub Brand: Bussmann Series
  • Type: Fuse
  • UNSPSC: 39121606
  • UPC 11: 05171254855
  • UPC 12: 051712548557
  • Width: 2.60 in
  • Width [Metric]: 6.6040 cm
  • Stock Status: NONSTOCK
  • Brand: Bussmann
  • Manufacturer: Eaton
  • Amperage Rating: 400 A
  • Class: RK-1
  • Interrupt Rating: 100 kAIC at 300 Vdc300 kAIC at 600 Vac
  • Voltage Rating: 600//300 VAC//VDC
400A 600V Class RK1 Low Peak Dual Element, Time Delay Fuse
QTY
  • Applications
  • Features
Ind Facilities & Factories - Facility: Safety and Security Systems
Electrically isolated end cap
Separate overload and short circuit elements provide time delay for close sizing of high inrush loads linked with RK1 current limitation and selective co-ordination ratio of 2:1 prevents widespread blackouts
Time delay permits 130% FLA sizing for backup motor protection
300 kA rms symmetrical interrupt rating provides adequate ratings without obsolescence for all electrical systems, big or small, allows for simple, worry free installation in virtually any application
Reduces existing fuse inventory by up to 33% when upgrading to Low-Peak® fuses
Consistent 2:1 ampacity ratios for all Low-Peak® fuses make selective co-ordination easy
Current limitation protects down stream components against damaging thermal and magnetic effects of short circuit currents
Protects against 1-phase motor damage
Proper sizing can provide "no damage" type 2 co-ordinated protection for NEMA and IEC motor controllers
Electrically isolated end cap
10 s at 500% of rated current response time
300 kA at 600 VAC, 100 kA at 300 VDC interrupt rating