Bussmann® JKS-70 LIMITRON™ JKS Current Limiting Fast Acting Fuse, 70 A, 600 VAC, 200 kA Interrupt, Class J Series
Class J Fuses
271627
MFG #: JKS-70
Bussmann
211.58000
/ ea
- Alternate Catalog Number: JKS-70
- Application: Ind Facilities & Factories - Facility: Safety and Security Systems
- ARRA Compliant: C
- Buy American Compliant: C
- Catalog Number: JKS-70
- Connection: Bolted Blade End X Bolted Blade End
- Country of Origin: MX
- Currency: USD
- Element: Single
- EU RoHS Indicator: C
- Gross Weight Per Pack: 0.3200 lb
- Gross Weight per Pack Metric: 0.13
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8536100040
- Height: 4.63 in
- Height [Metric]: 11.7602 cm
- Length: 4.63 in
- Length [Metric]: 11.7602 cm
- Size: 1.13 In Diameter X 4.63 In Length
- Standard: CE Marked,RoHS Compliant
- Standards: UL 248-8, CSA, CE Certified, RoHS Compliant
- Sub Brand: Bussmann Series
- Type: Fuse
- UNSPSC: 39121626
- UPC 11: 05171263070
- UPC 12: 051712630702
- Width: 1.13 in
- Width [Metric]: 2.8702 cm
- Stock Status: NONSTOCK
- Brand: Bussmann
- Manufacturer: Eaton
- Amperage Rating: 70 A
- Class: J
- Interrupt Rating: 200 kAIC at 600 Vac
- Voltage Rating: 600 V
Eaton's Bussmann series Limitron fuses provide short circuit protection that is, on average, 10X faster than basic circuit breakers or fuses. These current-limiting UL® and CSA Listed fuses are available in Class CC, J, R, and T - all with a 200kA interrupting rating.
- Brochure URL - COBUSSE01827_24.pdf(Brochure URL)
- http://www.bussmann.com(Seller Home Page URL)
- Spec Sheet 1 URL - Bussmann_JKS_100_Datasheet_1.pdf(Spec Sheet 1 URL)
- Spec Sheet URL - 10973_TGBOFYAWC79VKSQD.pdf(Spec Sheet URL)
- Spec Sheet URL - JKS-70(Spec Sheet URL)
- Spec Sheet URL - skuPage.JKS-70.pdf(Spec Sheet URL)
- Tech Bulletin URL - datasheet.php?model=FNQ-30&locale=en_GB(Tech Bulletin URL)
- Tech Drawing URL - bus-ele-cat-1007-01-lv-branch-fuses.pdf(Tech Drawing URL)
- Video - https://www.youtube.com/embed/YMvqUyoETXk(Video)
- Applications
- Features
Ind Facilities & Factories - Facility: Safety and Security Systems |
Non-indicating |
Provides component short circuit protection in compliance with NEC 110-10, where protection devices shall clear a fault without extensive damage in to the circuit components |
High interrupting rating helps meet the requirements of future system expansion and the increases in available utility short circuit current |
Fuses can be selectively coordinated with ease |
Current limitation for non-inductive circuits provides Class J current-limiting response to maximum ground fault and short circuit conditions |
Economical solutions for high fault circuits |
200 kA at 600 VAC (RMS symmetrical) |