Appleton® EYSEF300 Unilet® EY Series Explosionproof Conduit Sealing Fitting, 3 in, For Use With IMC/Threaded Rigid Metal Conduit
Explosion Proof Conduit Sealing Fittings
393966
MFG #: EYSEF300
Appleton™
602.93000
/ ea
- Application: For Use With Threaded Rigid Metal Conduit and IMC
- ARRA Compliant: N
- Buy American Compliant: N
- Catalog Number: EYSEF300
- Connection: Female Threaded
- Country of Origin: MX
- Currency: USD
- Dimensions: 9.19 in L x 4.75 in W
- EU RoHS Indicator: N
- Gross Weight Per Pack: 15.5100 lb
- Gross Weight per Pack Metric: 7.04
- Gross Weight UOM Metric: kg
- Height: 5.30 in
- Height [Metric]: 13.4620 cm
- Length: 10.80 in
- Length [Metric]: 27.4320 cm
- Series: EY Series
- Standard: UL 886 (1203), UL File Number E10444, CSA C22.2 No. 30, CSA 065181, UL Listed For Class I, Groups B, C, D; Class II, Groups E, F, G; And Class III
- Standards: UL 886UL 1203 File No. E10444CSA C22.2 No. 30CSA 065181, Class I, Groups B, C, D, Class II, Groups E, F, G, Class III
- Sub Brand: UNILETS
- Type: Dust-Ignitionproof Explosionproof Raintight
- UNSPSC: 39121311
- UPC 11: 78138169435
- UPC 12: 781381694353
- Width: 7.60 in
- Width [Metric]: 19.3040 cm
- Stock Status: NONSTOCK
- Brand: Appleton™
- Manufacturer: Appleton
- Finish: Zinc Electroplate/Chromate/Epoxy Powder Coat
- Material: Malleable Iron
- Size: 3 in
- Suitable For Use With: IMC/Threaded Rigid Metallic Conduit
These sealing fittings minimizes the passage of gases and vapors and prevents the passage of flames from oneportion of a conduit system to another. they prevent pressure piling the within conduit system and contain any explosion that occurs. The EY series is a close radius type for sealing vertical or horizontal conduit runs.
- Applications
- Features
For Use With Threaded Rigid Metal Conduit and IMC |
For preventing passage of gases, vapors or flames from one portion of conduit system to another; Required in Class I, Division 1 and 2 locations within 18 IN of enclosures containing apparatus that may cause arcs, sparks or high temperatures; Required in Class I, Division 1 and 2 locations where 2 IN or larger conduit enters enclosure, fitting housing terminals, splices or taps; Required in Class I, Division 1 and 2 locations at the boundary where conduit leaves classified location; Required in Class I, Division 1 and 2 locations where two or more enclosures are connected by 36 IN or less conduit, seal must be located within 18 IN of either enclosure; Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in Class I, Division 2 locations; Explosionproof, dust-ignitionproof, raintight; Smooth, rounded integral bushing in each hub protects conductor insulation; Accurately tapped, tapered threads for tight, rigid joints and ground continuity; A |
Smooth, rounded integral bushing in each hub protects conductor insulation |
Accurately tapped, tapered threads for tight, rigid joints and ground continuity |
Dust-ignition proof, raintight |
Removable nipple in male sealing fitting may be used interchangeably in top or bottom hub |
Close radius type for sealing vertical or horizontal conduit runs |
Restrict any explosion to the sealed off enclosure |
Required in class I, Division 1 and 2 locations within 18 in of enclosures containing apparatus that may cause arcs, sparks or high temperatures |
Required in class I, Division 1 and 2 locations where 2 in or larger conduit enters enclosure, fitting housing terminals, splices or taps |
Required in class I, Division 1 and 2 locations at the boundary where conduit leaves classified location |
Required in class I, Division 1 and 2 locations where two or more enclosures are connected by 36 in or less conduit, seal must be located within 18 in of either enclosure |
Required where cables (which exceed rate of gas or vapor transmission permitted for seals) are used in class I, Division 2locations |
3.31 in turning radius |
Female threaded connection |
40% fill expanded fill sealing fittings for close turning radius |
Triple-coat (Zinc electroplate, chromate and epoxy powder coat) finish |