Appleton® EXGJH-14-SS STAINLESS STEEL FLEXIBLE COUP

Explosion Proof Conduit Couplings
392273 MFG #: EXGJH14SS
Appleton™
174.15000 / ea
  • Application: For Use With Threaded Rigid Metal Conduit And IMC
  • ARRA Compliant: C
  • Buy American Compliant: N
  • Catalog Number: EXGJH14SS
  • Connection: Female Threaded
  • Country of Origin: MX
  • Currency: USD
  • EU RoHS Indicator: C
  • Flexibility: Rigid And IMC
  • Gross Weight Per Pack: 4.0000 lb
  • Gross Weight per Pack Metric: 1.81
  • Gross Weight UOM Metric: kg
  • Height: 2.50 in
  • Height [Metric]: 6.3500 cm
  • Length: 12.50 in
  • Length [Metric]: 31.7500 cm
  • Outside Diameter: 1.41 in
  • Radius: 10 IN Bending in
  • Standard: UL 886 (1203), UL File Number E10444, CSA C22.2 No. 25, C22.2 No. 30, CSA 065181 Certified, Class I, Division 1 And 2 And Class II, Division 1 And 2, Suitable For Class I, Groups A, B, C, D; Class II, Groups E, F, G; Class III
  • Sub Brand: UNILETS
  • Trade Size: 0.5 in
  • Type: Flexible Coupling
  • UNSPSC: 39131707
  • UPC 11: 78138161174
  • UPC 12: 781381611749
  • Width: 5.00 in
  • Width [Metric]: 12.7000 cm
  • Stock Status: NONSTOCK
  • Brand: Appleton™
  • Manufacturer: Appleton
  • Material: Outer Bronze Braid And Inner Brass Core With Insulating Liner
UNILETS Flexible Coupling, Trade Size: 1/2 IN, Outside Diameter: 1.41 IN, Flex Length: 14 IN, Radius: 10 IN Bending, Flexibility: Rigid And IMC, Material: Natural Finished Stainless Steel Braid/CoreOuter With Insulating Liner, End Type: (2) Male Nipples, Standard: UL 886 (1203), UL File Number E10444, CSA C22.2 No. 25, C22.2 No. 30, CSA 065181 Certifed, Class I, Division 1 And 2 And Class II, Division 1 And 2, Suitable For Class I, Groups A, B, C, D, Class II, Groups E, F, G, Class III, For Use With Threaded Rigid Metal Conduit And IMC
QTY
  • Applications
  • Features
For Use With Threaded Rigid Metal Conduit And IMC
Explosionproof, dust-ignitionproof, watertight; Smooth, rounded integral bushing in each hub protects conductor insulation; Accurately tapped, tapered threads for tight, rigid joints and ground continuity; Heavy duty design resists mechanical abuse; Electrical conductivity equal to rigid conduit on a similar length basis no bonding jumper required; Interior insulating liner protects conductors from abrasion under vibrating conditions; Female end fitting with removable ductile iron union at one end and a female end fitting with a removable brass male nipple at the other end; Used in areas where vibration and movement is a problem, also used in place of rigid conduit in difficult-bend situations