Siemens DTNF323R DTSS NF 3P3W 240V 100A N3R

Double Throw Safety Switches
718289 MFG #: DTNF323R
Siemens
1289.02000 / ea
  • Actuator: DOUBLETHROW
  • Actuator Type: Handle
  • Alternate Catalog Number: US2:DTNF323R
  • Application: LOADTRANSFERBETWEENPOWERSOURCES
  • ARRA Compliant: C
  • Buy American Compliant: C
  • Catalog Number: DTNF323R
  • Connection: MECHANICALLUGS
  • Country of Origin: MX
  • Currency: USD
  • Dimensions: 27.62 in H x 12.18 in W x 6.09 in D
  • Enclosure: NEMA3R
  • Enclosure Type: NEMA 3R
  • EU RoHS Indicator: C
  • Frequency Rating: 60 Hz
  • Gross Volume Per Pack: 3360.01
  • Gross Volume UOM: in
  • Gross Weight Per Pack: 46.8000 lb
  • Gross Weight per Pack Metric: 21.23
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8536509045
  • Height: 11.00 in
  • Height [Metric]: 27.9400 cm
  • Insulation Type: Non-Insulated
  • Length: 32.20 in
  • Length [Metric]: 81.7880 cm
  • Material: 304 Stainless Steel
  • Mounting: Surface
  • Mounting Type: 2/3-Point Hole
  • Number of Wires: 3
  • Operating Temperature: -29 °C
  • Returnable: Y
  • Short Circuit Current Rating: 200 kA
  • Standard: UL98
  • Standards: ARRA CompliantBuy American Act CompliantRoHS CompliantUL Listed
  • Sub Brand: VBII
  • Switch Type: DOUBLETHROW
  • Temperature Rating: -20 to 120 °F
  • Terminal Type: Lug
  • Type: Enclosed Heavy Duty Non-Fused
  • UNSPSC: 39122205
  • UPC 11: 78364345416
  • UPC 12: 783643454163
  • Width: 17.20 in
  • Width [Metric]: 43.6880 cm
  • Stock Status: NONSTOCK
  • Brand: Siemens
  • Manufacturer: Siemens
  • Amperage Rating: 100 A
  • Contact Form: TPDT
  • Horsepower: 40 hp
  • Voltage Rating: 240 VAC
  • Number Of Poles: 3
Double throw safety switches are intended to transfer loads from one power source to another. All 2 and 3-pole double throw switches are suitable for use as service equipment. All are UL Listed. Switches are rated for use on systems up to 10000 A when protected with class H fuses or 100000 A when protected with class R or class T fuses. They can also be used to connect a single source of power to either of two loads. In this application it is necessary to field modify fusible switches so that the fuses are on the load side of the switching mechanism. A cover interlock is provided on all ampere ratings. The operating handle may be padlocked in the OFF position.
QTY
  • Applications
  • Features
LOADTRANSFERBETWEENPOWERSOURCES
Without insulation
10000 operating cycles
2 W power
2 or 3 point mounting holes
Less neutral
240 VAC/250 VDC
Outdoor environmental conditions