Square D™ EZ Meter-Pak™ EZM31200GCBUMS Main Circuit Breaker Meter Center Main Unit, 120/240 VAC, 208Y/120 VAC, 1200 A, 3 ph Phase, NEMA 3R Enclosure

Meter Mains
PDW~12315386 MFG #: EZM31200GCBUMS
Square D™
33816.80000 / ea
  • Alternate Catalog Number: EZM31200GCBUMS
  • Application: Indoor/Outdoor Applications
  • ARRA Compliant: N
  • Buy American Compliant: N
  • Cable Entry: UG
  • Catalog Number: EZM31200GCBUMS
  • Country of Origin: MX
  • Currency: USD
  • Enclosure: Galvannealed steel;Powder Coated Steel
  • EU RoHS Indicator: Y
  • Gross Volume Per Pack: 81432.00
  • Gross Volume per Pack Metric: 1334426.18
  • Gross Volume UOM: CI
  • Gross Volume UOM Metric: cm3
  • Gross Weight Per Pack: 341.2840 lb
  • Gross Weight per Pack Metric: 155.13
  • Gross Weight UOM Metric: kg
  • Harmonization Tariff Schedule Code: 8537109170
  • Height: 64.70 in
  • Height [Metric]: 165.9000 cm
  • Item Group: 00020
  • Length: 13.49 in
  • Length [Metric]: 34.6000 cm
  • Material Composition Declaration: https://checkaproduct.se.com/DistantRequestDispatcher.aspx?action=export&pid=455794963&lang=en-us
  • Mounting: WALL MOUNTED
  • Returnable: Y
  • Size: 65.30 in
  • Standard: UL Listed
  • UNSPSC: 39121102
  • UPC 11: 78590108955
  • UPC 12: 785901089551
  • Width: 23.48 in
  • Width [Metric]: 60.2000 cm
  • Brand: Square D™
  • Manufacturer: Schneider Electric
  • Amperage Rating: 1200 A,1200 A
  • Phase: 3 phase in;3 phase out
  • Type: Meter center main unit
  • Voltage Rating: 120/240 V AC-208Y/120 V AC
Square D™ EZ Meter-Pak™ Meter Center Main Unit, Main Circuit Breaker, 120/240 VAC, 208Y/120 VAC, 1200 A, 3 ph, Underground Feed, (4) 3/0 AWG to 500 kcmil Wire, Wall Mounting, NEMA 3R Enclosure, 23.69 in W x 13.63 in D x 65.3 in H Dimensions
QTY
  • Applications
  • Features
Indoor/Outdoor Applications
Main Circuit Breaker;Copper busbar
VISI-TITE™ nut and bolt make installation faster and easier by eliminating the need for special tools or time-consuming torque readings
Circuit breaker, fusible switch and terminal box mains from 400 to 1600 A maximum
Suitable for use as service equipment
Unique field phase-balancing allows easy on-site changing of phase-balancing
External mounting channels permits immediate installation with no disassembly or adjustment required
Mounting brackets swing out of the way, allowing mounting holes to be drilled without moving the device
Top and bottom wiring gutters allow branch circuits to exit from the top, bottom or back of the unit
Single, double and three position meter-breaker units can be connected in any combination, providing a solution for any size application
When installed, main terminal boxes do not protrude past adjacent meter center, complying with EUSERC's required spacing around installed meters