Siemens 3RV2 Motor Protection Circuit Breaker, 690 VAC, 45 to 63 A, 3 kA Interrupt, 3 Poles, Magnetic Trip
Motor Protection Circuit Breakers
1044640
MFG #: 3RV20414JA10
Siemens
606.40000
/ ea
- Alternate Catalog Number: 3RV2041-4JA10
- ARRA Compliant: C
- Buy American Compliant: C
- Catalog Number: 3RV20414JA10
- Connection Type: Screw
- Country of Origin: DE
- Currency: USD
- Dimensions: 165 mm H x 70 mm W x 176 mm D
- Enclosure Type: IP00/IP20
- EU RoHS Indicator: C
- Frame: S3
- Frequency Rating: 50/60 Hz
- Gross Volume Per Pack: 247.64
- Gross Volume UOM: in
- Gross Weight Per Pack: 4.9200 lb
- Gross Weight per Pack Metric: 2.23
- Gross Weight UOM Metric: kg
- Harmonization Tariff Schedule Code: 8536304000
- Height: 7.5500 in
- Height [Metric]: 19.1770 cm
- Length: 8.2000 in
- Length [Metric]: 20.8280 cm
- Mounting Type: DIN Rail/Snap-On/Threaded
- Phase: 3
- Power Rating: 55 kW
- Returnable: Y
- Series: 3RV2
- Standards: CCC CertifiedCSA CertifiedUL ListedEAC ApprovedEX ATEXIECEx CertifiedCE CertifiedVDE ApprovedABS ApprovedLloyd's RegisteredPRS CertifiedRINA CertifiedRMRS ApprovedDNV-GL ApprovedEN 60715
- Temperature Rating: -20 to 60 °C
- Trip Range: 45 to 63 A, 819 A
- UNSPSC: 39121521
- UPC 11: 80476637015
- UPC 12: 804766370151
- Width: 4.0000 in
- Width [Metric]: 10.1600 cm
- Wire Size: 2.5 to 50 sq-mm, 10 to 70 sq-mm
- Stock Status: NONSTOCK
- Brand: Siemens
- Manufacturer: Siemens
- Amperage Rating: 63 A
- Interrupt Rating: 5 kA
- Trip Type: Thermomagnetic
- Voltage Rating: 690 VAC
- Number Of Poles: 3
The SIRIUS 3RV2 motor starter protectors/circuit breakers are compact, current limiting motor starter protectors/circuit breakers which are optimized for load feeders. The motor starter protectors/circuit breakers are used for switching and protecting three-phase motors of up to 55/45 kW at 400 VAC and for other loads with rated currents of up to 100 A.
- 3D Rendering URL - G_IC03_XX_18993V.pdf(3D Rendering URL)
- http://www.sea.siemens.com(Seller Home Page URL)
- Spec Sheet URL - DatasheetService?format=PDF&caller=PDPS&mlfbs=3RV2041-4JA10&language=en(Spec Sheet URL)
- Spec Sheet URL - DatasheetService?format=PDF&caller=EGH&mlfbs=3RV20414JA10&language=en(Spec Sheet URL)
- Spec Sheet URL - 10991_0XVFQP87WGZCTHSK.pdf(Spec Sheet URL)
- Spec Sheet URL - DatasheetService?format=PDF&caller=EGH&mlfbs=3RV2041-4JA10&language=en(Spec Sheet URL)
- User Manual URL - man(User Manual URL)
- Features
Minimization of energy losses through optimization of the bimetal trip units |
Reduction of inherent power loss |
Less heating of the control cabinet |
Smaller control cabinet air conditioners can be used |
3RV2 motor starter protectors/circuit breakers are suitable for operation in IT systems (IT networks) |
18500 W at 230 VAC, 30000 W at 400 VAC, 37000 W at 500 VAC, 55000 W at 690 VAC |
100 kA at 240 VAC, 65 kA at 400 VAC, 12 kA at 500 VAC, 5 kA at 690 VAC |
45 to 63 A thermal overload release, 819 A instantaneous overcurrent release |
Without auxiliary switch |