Banner Engineering Mini-Beam® SM2A31R Receiver, Rectangle Shape, 3000 mm Sensing, Infrared Sensing Beam

Thru-Beam, Block/Slot Style Receiver
13469 MFG #: SM2A31R
BANNER®
148.03000 / ea
  • Application: For Use With SMA31 Series Photoelectric Sensor Emitter
  • Catalog Number: SM2A31R
  • Connection: 2 MR Cable
  • Country of Origin: USA
  • Enclosure: IEC IP67 NEMA 1, 2, 3, 3S, 4, 4X, 12 and 13 Thermoplastic Reinforced VALOX
  • Environmental Conditions: 90 PCT At 50 ° C Relative Humidity
  • Gross Weight Per Pack: 1 lb
  • Leakage Current: Off-State Output: Less Than 1.7 MILAMP
  • Lens: Acrylic
  • Operating Temperature: -20 To 70
  • Size: 65.8 MM Length X 12 MM Width X 33.3 MM Height X 18 MM Barrel Diameter
  • Standards: CE Marked, CSA Approval, UL Approval
  • Type: Opposed Mode Receiver
  • UNSPSC: 39121528
  • UPC 11: 66248826060
  • UPC 12: 66248826060
  • Voltage Rating: 24 - 240 V
  • Stock Status: NONSTOCK
  • Brand: BANNER®
  • Manufacturer: Banner Engineering Corp.
  • Response Time: 2 ms On/1 ms Off
  • Sensing Beam: 880 NMTR Infrared LED
  • Sensing Range: 3
Banner Engineering Mini-Beam® Receiver, Rectangle, Opposed Sensing Method, 3000 mm Sensing Range, Infrared Sensing Beam, 2 ms On/1 ms Off Response, Solid State AC Switch Output, 24 to 240 VAC, Cable, LED Light Source, NEMA 1/2/3/3S/4/4X/6/12/13/IP67, -20 to 70 deg C Operating, Environmental Conditions: 90% at 50 deg C Relative Humidity
QTY
  • Applications
  • Features
For Use With SMA31 Series Photoelectric Sensor Emitter
Rectangular with M18 barrel housing style; Compact, self-contained, modulated, highly repeatable sensors; Switch-selectable for light operate or dark operate; Physically and electrically interchangeable with 18 MM barrel-type photoelectric; Rugged, epoxy-encapsulated, totally encapsulated, O-ring sealing and stainless steel screws construction; Protected against transient voltages and against false pulse on power-up; Controls are located on rear panel of sensor and protected by a gasketed, clear acrylic cover; MINI-BEAMs may be destroyed from overload conditions; Use on low voltage requires careful analysis of the load to determine if the leakage current or on-state voltage of the sensor will interfere with proper operation of the load; The false-pulse protection feature may cause momentary drop-out of the load when the sensor is wired in series or paral
Thermoplastic primary housing material
Light/dark operate
300 us repeatability
Acrylic lens material
Potentiometer adjustment
18 mm barrel diameter
Opposed mode receiver
Solid state AC switch input/output
300 ms delay at power-up
2 m cable connection
Rectangular with M18 mount
2 m length cable connection